CSAS Pressure Sensor Fault
TASK 21-58-00-810-806-A
CSAS Pressure Sensor Fault
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 21-58-00-710-060-A ** ON A/C NOT FOR ALL
Subtask 21-58-00-810-086-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:24:49 UTC
CSAS Pressure Sensor Fault
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 215301 | |
| AMM 21-58-00-710-001 | Operational Test of the Conditioned Service Air System without Bleed Air |
| AMM 21-58-00-710-002 | Operational Test of the Conditioned Service Air System with Bleed Air |
| AMM 21-58-12-000-001 | Removal of the Pressure Sensor |
| AMM 21-58-12-400-001 | Installation of the Pressure Sensor |
| AMM 34-10-00-860-002 | ADIRS Start Procedure |
| AMM 47-10-43-920-001 | Air Separator Module Replacement |
Subtask 21-58-00-710-060-A ** ON A/C NOT FOR ALL
A. Test
(1) Make sure that the ADIRU is activated AMM 34-10-00-860-002.
(2) Do the operational test of the conditioned service air system without bleed air AMM 21-58-00-710-001.
(3) Do the operational test of the conditioned service air system with bleed air AMM 21-58-00-710-002.
4. Fault Isolation(1) Make sure that the ADIRU is activated AMM 34-10-00-860-002.
(2) Do the operational test of the conditioned service air system without bleed air AMM 21-58-00-710-001.
(3) Do the operational test of the conditioned service air system with bleed air AMM 21-58-00-710-002.
Subtask 21-58-00-810-086-A ** ON A/C NOT FOR ALL
A. If the system test without bleed gives a different maintenance message, do the related trouble shooting procedure.
Subtask 21-58-00-810-071-A ** ON A/C NOT FOR ALL B. If the system test with bleed gives the maintenance message CSAS PRESS SNSR (117HW):
Subtask 21-58-00-810-055-A ** ON A/C NOT FOR ALL - replace the SENSOR-PRESS,CSAS [117HW] AMM 21-58-12-000-001 and AMM 21-58-12-400-001.
- do a check and repair the wiring from:
- the CSAS PRESSURE SENSOR (117HW) the CSAS CONTROL UNIT (100HW) and,
- the CSAS PRESSURE SENSOR (117HW) to ground ASM 215301.
- replace the ASM [1YM] AMM 47-10-43-920-001.
C. If the system test with bleed gives a different maintenance message, do the related trouble shooting procedure.
Subtask 21-58-00-710-061-A ** ON A/C NOT FOR ALL D. Do the test as given in the Para. 3.A.