W DOC AIRBUS | TSM A320F

CSAS Pressure Sensor Fault


TASK 21-58-00-810-806-A
CSAS Pressure Sensor Fault


1. Possible Causes
  • SENSOR-PRESS,CSAS [117HW]
  • wiring
  • ASM [1YM]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 215301
AMM 21-58-00-710-001
Operational Test of the Conditioned Service Air System without Bleed Air
AMM 21-58-00-710-002
Operational Test of the Conditioned Service Air System with Bleed Air
AMM 21-58-12-000-001
Removal of the Pressure Sensor
AMM 21-58-12-400-001
Installation of the Pressure Sensor
AMM 34-10-00-860-002
ADIRS Start Procedure
AMM 47-10-43-920-001
Air Separator Module Replacement
3. Fault Confirmation
Subtask 21-58-00-710-060-A ** ON A/C NOT FOR ALL
A. Test
   (1) Make sure that the ADIRU is activated AMM 34-10-00-860-002.
   (2) Do the operational test of the conditioned service air system without bleed air AMM 21-58-00-710-001.
   (3) Do the operational test of the conditioned service air system with bleed air AMM 21-58-00-710-002.
4. Fault Isolation
Subtask 21-58-00-810-086-A ** ON A/C NOT FOR ALL
A. If the system test without bleed gives a different maintenance message, do the related trouble shooting procedure.
Subtask 21-58-00-810-071-A ** ON A/C NOT FOR ALL
B. If the system test with bleed gives the maintenance message CSAS PRESS SNSR (117HW):
   (1) If the fault continues:
  • do a check and repair the wiring from:
  • the CSAS PRESSURE SENSOR (117HW) the CSAS CONTROL UNIT (100HW) and,
  • the CSAS PRESSURE SENSOR (117HW) to ground ASM 215301.
   (2) If the fault continues:
Subtask 21-58-00-810-055-A ** ON A/C NOT FOR ALL
C. If the system test with bleed gives a different maintenance message, do the related trouble shooting procedure.
Subtask 21-58-00-710-061-A ** ON A/C NOT FOR ALL
D. Do the test as given in the Para. 3.A.
[Rev.8 from Aug 2018] 2026.04.04 04:24:49 UTC