CSAS Heat Exchanger Fault
TASK 21-58-00-810-803-A
CSAS Heat Exchanger Fault
1. Possible Causes
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Referenced Information
3. Fault Confirmation
Subtask 21-58-00-810-073-A ** ON A/C NOT FOR ALL
Subtask 21-58-00-810-052-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:24:49 UTC
CSAS Heat Exchanger Fault
1. Possible Causes
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | WATER - SOAPY SOLUTION |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.14CCB6) | Testing Medium-Leak Detection - Oxygen System |
| REFERENCE | DESIGNATION |
|---|---|
| AMM 21-58-00-710-002 | Operational Test of the Conditioned Service Air System with Bleed Air |
Subtask 21-58-00-810-073-A ** ON A/C NOT FOR ALL
A. Access
(1) Get access to the CSAS heat exchanger area.
Subtask 21-58-00-710-054-A ** ON A/C NOT FOR ALL (1) Get access to the CSAS heat exchanger area.
B. Test.
(1) Apply a solution of Testing Medium-Leak Detection - Oxygen System (Material No.14CCB6) or WATER - SOAPY SOLUTION to all components and ducts of the Fuel Tank Inerting System in the area of the CSAS Heat Exchanger (5103HM) to search for a leak.
(2) Do the operational test of the conditioned service air system with bleed air AMM 21-58-00-710-002.
(3) Do a check for leakages in the area of the CSAS Heat Exchanger (5103HM) while and immediately after the system test with bleed.
4. Fault Isolation(1) Apply a solution of Testing Medium-Leak Detection - Oxygen System (Material No.14CCB6) or WATER - SOAPY SOLUTION to all components and ducts of the Fuel Tank Inerting System in the area of the CSAS Heat Exchanger (5103HM) to search for a leak.
(2) Do the operational test of the conditioned service air system with bleed air AMM 21-58-00-710-002.
(3) Do a check for leakages in the area of the CSAS Heat Exchanger (5103HM) while and immediately after the system test with bleed.
Subtask 21-58-00-810-052-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message HEAT EXCHGR (5103HM) and if there is a leakage detected:
1 clean the Heat Exchanger (5103HM).
Subtask 21-58-00-710-055-A ** ON A/C NOT FOR ALL - remove the leakage by replacement of the faulty component.
- do a check of the CSAS Heat Exchanger and the Ram Air Channel for contamination.
1 clean the Heat Exchanger (5103HM).
B. Do the test as given in the Para. 3.B.