CSAS Heat Exchanger Fault


TASK 21-58-00-810-803-A
CSAS Heat Exchanger Fault


1. Possible Causes

2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
WATER - SOAPY SOLUTION
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.14CCB6)
Testing Medium-Leak Detection - Oxygen System
 C. Referenced Information
REFERENCE
DESIGNATION
AMM 21-58-00-710-002
Operational Test of the Conditioned Service Air System with Bleed Air
3. Fault Confirmation
Subtask 21-58-00-810-073-A ** ON A/C NOT FOR ALL
A. Access
   (1) Get access to the CSAS heat exchanger area.
Subtask 21-58-00-710-054-A ** ON A/C NOT FOR ALL
B. Test.
   (1) Apply a solution of Testing Medium-Leak Detection - Oxygen System (Material No.14CCB6) or WATER - SOAPY SOLUTION to all components and ducts of the Fuel Tank Inerting System in the area of the CSAS Heat Exchanger (5103HM) to search for a leak.
   (2) Do the operational test of the conditioned service air system with bleed air AMM 21-58-00-710-002.
   (3) Do a check for leakages in the area of the CSAS Heat Exchanger (5103HM) while and immediately after the system test with bleed.
4. Fault Isolation
Subtask 21-58-00-810-052-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message HEAT EXCHGR (5103HM) and if there is a leakage detected:
  • remove the leakage by replacement of the faulty component.
   (1) If the fault continues:
  • do a check of the CSAS Heat Exchanger and the Ram Air Channel for contamination.
     (a) If the Heat Exchanger is contaminated:
       1 clean the Heat Exchanger (5103HM).
Subtask 21-58-00-710-055-A ** ON A/C NOT FOR ALL
B. Do the test as given in the Para. 3.B.