CSAS Isolation Valve Fault


TASK 21-58-00-810-802-A
CSAS Isolation Valve Fault


1. Possible Causes
  • VALVE-ISOLATION,CSAS [111HW]
  • wiring
  • CSAS Heat Exchanger (5103HM) drain hole
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 215301
AMM 21-58-00-710-002
Operational Test of the Conditioned Service Air System with Bleed Air
AMM 21-58-51-000-001
Removal of the CSAS Isolation Valve
AMM 21-58-51-400-001
Installation of the CSAS Isolation Valve
3. Fault Confirmation
Subtask 21-58-00-710-052-A ** ON A/C NOT FOR ALL
A. Do the operational test of the conditioned service air system with bleed air AMM 21-58-00-710-002.
4. Fault Isolation
Subtask 21-58-00-810-051-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message CSAS ISOL VLV (111HW):
   (1) If the fault continues:
  • do a check and repair the wiring from:
  • the CSAS ISOLATION VALVE (111HW) AA to the CSAS CONTROL UNIT (100HW) AB/5A,
  • the CSAS ISOLATION VALVE (111HW) AH to the CSAS CONTROL UNIT (100HW) AB/8A and,
  • the CSAS ISOLATION VALVE (111HW) to ground ASM 215301.
   (2) If the fault continues:
  • do a check and clean the CSAS Heat Exchanger (5103HM) drain hole.
Subtask 21-58-00-710-053-A ** ON A/C NOT FOR ALL
B. Do the test as given in the Para. 3.A.