Emergency Ram Air Inlet Fault
TASK 21-55-00-810-803-A
Emergency Ram Air Inlet Fault
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 21-55-00-710-054-A 4. Fault Isolation
Subtask 21-55-00-810-053-A
[Rev.8 from Aug 2018]
2026.04.04 04:24:49 UTC
Emergency Ram Air Inlet Fault
1. Possible Causes
- P/BSW-AIR COND/RAM RAM AIR [4HZ]
- RELAY-RAM AIR OPENING CTL [5HZ]
- RELAY-RAM AIR CLOSE CTL [3HZ]
- EMERG RAM AIR ACTUATOR [7HZ]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 21-55-00-710-001 | Operational Test of the Emergency Ram-Air Inlet |
| ASM 215501 | |
| AMM 21-55-51-000-001 | Removal of the Emergency Ram Air Inlet Actuator |
| AMM 21-55-51-400-001 | Installation of the Emergency Ram Air Inlet Actuator |
| AWM 315452 |
Subtask 21-55-00-710-054-A 4. Fault Isolation
Subtask 21-55-00-810-053-A
A. If during the test the ram air symbol does not change from GREEN (CLOSED) to AMBER (OPEN) within the maximum operation time of 20 seconds:
Subtask 21-55-00-710-055-A - replace the P/BSW-AIR COND/RAM RAM AIR [4HZ] .
- replace the RELAY-RAM AIR OPENING CTL [5HZ] .
- replace the RELAY-RAM AIR CLOSE CTL [3HZ] .
- replace the EMERG RAM AIR ACTUATOR [7HZ] AMM 21-55-51-000-001 and AMM 21-55-51-400-001.
- do a check and repair the wiring :
- from the EMERG RAM AIR ACTUATOR A/B, F to the SDAC-1 (1WV1) AA/9F, 10F,
- from the EMERG RAM AIR ACTUATOR A/B, F to the SDAC-2 (1WV2) AA/9F, 10F,
- from the EMERG RAM AIR ACTUATOR A/D, H to the GND,
- from the RAM AIR pushbutton switch (4HZ) A/J to the SDAC-1 (1VW1) AA/9G,
- from the RAM AIR pushbutton switch (4HZ) A/J to the SDAC-2 (1WV2) AA/9G,
- from the RAM AIR pushbutton switch (4HZ) A/D3 to the GND,
- from the EMERG RAM AIR ACTUATOR to the circuit breaker (1HZ), via the relay (5HZ), the RAM AIR pushbutton switch (4HZ) and the relay (3HZ).
B. Do the test given in Para. 3.