Emergency Ram Air Inlet does not close in Ditching Configuration
TASK 21-55-00-810-802-A
Emergency Ram Air Inlet does not close in Ditching Configuration
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 21-55-00-710-052-A
Subtask 21-55-00-810-052-A
[Rev.8 from Aug 2018]
2026.04.04 04:24:49 UTC
Emergency Ram Air Inlet does not close in Ditching Configuration
1. Possible Causes
- RELAY-RAM AIR CLOSE CTL [3HZ]
DITCHING pushbutton switch (13HL) - wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 21-55-00-810-801-A | Emergency Ram Air Inlet Fault |
| AMM 21-55-00-710-002 | Operational Test of Emergency Ram-Air Inlet and Flow Control Valve Closing in Ditching Configuration |
| ASM 215501 |
Subtask 21-55-00-710-052-A
A. Do the operational test of the emergency ram air inlet system-closing in ditching configuration AMM 21-55-00-710-002.
4. Fault IsolationSubtask 21-55-00-810-052-A
A. If during the test on the lower ECAM display the ram air symbol is replaced by an amber XX:
Subtask 21-55-00-810-051-A - do the trouble shooting of the emergency ram air inlet fault (Ref. TSM TASK 21-55-00-810-801).
B. If during the test the emergency ram air inlet does not close in ditching configuration:
Subtask 21-55-00-710-053-A - replace the RELAY-RAM AIR CLOSE CTL [3HZ] .
- replace the
DITCHING pushbutton switch (13HL) .
- do a check and repair the wiring from the DITCHING pushbutton switch (13HL) to the circuit breaker (1HZ), via the the relay (3HZ) ASM 215501.
C. Do the test given in Para. 3.