W DOC AIRBUS | TSM A320F

Pack 2 P/BSW Fault


TASK 21-51-00-810-826-A
Pack 2 P/BSW Fault


1. Possible Causes
  • P/BSW-AIR COND/PACK 2 [6HB]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 215101
AMM 21-61-00-710-001
Operational Test of the Pack Temperature-Control System
3. Fault Confirmation
Subtask 21-51-00-710-087-A ** ON A/C NOT FOR ALL
A. Do the operational test of the pack temperature-control system AMM 21-61-00-710-001.
4. Fault Isolation
Subtask 21-51-00-810-103-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message PACK P-B(6HB) / WIRING:
  • do a check of the P/BSW-AIR COND/PACK 2 [6HB] and replace it if necessary ASM 215101.
   (1) If the fault continues:
  • do a check and repair the wiring ASM 215101 from:
  • the CONT-AIR COND SYSTEM 2 (57HH) to the
    PUSHBUTTON SWITCH-AIR COND/PACK 1 (6HB).
Subtask 21-51-00-720-061-A ** ON A/C NOT FOR ALL
B. Do the test as given in the Para. 3.A.
[Rev.8 from Aug 2018] 2026.04.04 04:24:49 UTC