Pack 2 High Flow Indication
TASK 21-51-00-810-816-A
Pack 2 High Flow Indication
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 21-51-00-860-077-A
Subtask 21-51-00-810-088-A ** ON A/C NOT FOR ALL
Subtask 21-51-00-720-063-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:24:48 UTC
Pack 2 High Flow Indication
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 21-51-00-810-814-A | Pack 2 Flow Indication Fault |
| AMM 12-33-21-618-001 | Pre-conditioning through the LP Ground Connection |
| ASM 215101 | |
| AMM 21-51-51-000-001 | Removal of the Pack Flow-Control Valve/ Pack Flow-Control Unit |
| AMM 21-51-51-400-001 | Installation of the Pack Flow-Control Valve/ Pack Flow-Control Unit |
| AMM 71-00-00-710-003 | Engine Automatic Start |
Subtask 21-51-00-860-077-A
A. Bleed Air Supply Source from the HP Ground Connection
(2) On the AIR COND panel 30VU:
Subtask 21-51-00-860-075-A ** ON A/C NOT FOR ALL 4. Fault IsolationNOTE: The HP ground supply source must be able to give a pack inlet pressure of 24 PSI minimum. If it can not do this then you must get the bleed air supply from the engines.
The work steps which follow show the conditions necessary before you get the minimum pack-inlet pressure.
(1) Do the pre-conditioning through the HP ground connection AMM 12-33-21-618-001. The work steps which follow show the conditions necessary before you get the minimum pack-inlet pressure.
(2) On the AIR COND panel 30VU:
- push the HOT AIR pushbutton switch to the on position (the OFF legend goes off),
- turn the COCKPIT, FWD CABIN and the AFT CABIN temperature selectors to the HOT positions and,
- make sure that the PACK 1 and the PACK 2 pushbutton switches are in the on position (the OFF legends are off).
- make sure that the pack 1 inlet pressure indication shows a minimum of 24 PSI.
NOTE: If the indication shows less than 24 PSI you must:
- increase the ground pressure supply until the indication shows a minimum of 24 PSI.
Subtask 21-51-00-810-088-A ** ON A/C NOT FOR ALL
A. When the pack flow selector is at the LO or NORM position:
Subtask 21-51-00-810-088-B ** ON A/C NOT FOR ALL - on the upper ECAM DU if the pack 2 flow shows in the HI flow position and both pack flow-control valve indications show green,
- replace the P1 FLOW CTL VALVE [11HB] AMM 21-51-51-000-001 and AMM 21-51-51-400-001.
- do the trouble shooting procedures for the pack 2 flow indication fault (Ref. TSM TASK 21-51-00-810-814).
A. When the pack flow selector is at the LO or NORM position:
Subtask 21-51-00-810-105-A ** ON A/C NOT FOR ALL - on the upper ECAM DU if the pack 2 flow shows in the HI flow position and both pack flow-control valve indications show green,
- replace the FLOW CTL UNIT - PACK 1 [23HB] AMM 21-51-51-000-001 and AMM 21-51-51-400-001.
- do the trouble shooting procedures for the pack 2 flow indication fault (Ref. TSM TASK 21-51-00-810-814).
B. This procedure is only applicable for the Flow Control Valves P/N 1303 series.
(1) When the pack flow selector is at the LO or NORM position:
a replace the P1 FLOW CTL VALVE [11HB] AMM 21-51-51-000-001 and AMM 21-51-51-400-001.
(2) If the fault continues:
5. Close-up(1) When the pack flow selector is at the LO or NORM position:
- on the upper ECAM DU if the pack 2 flow shows in the HI flow position and both pack flow-control valve indications show green,
- the FCV (11HB/A) pin C to the PACK2 TEMP CONTROLLER (27HH/AA) pin 7B,
- the FCV (11HB/A) pin B to ground.
- do a check for continuity between pin A/B and pin A/C of the P1 FLOW CTL VALVE (11HB).
a replace the P1 FLOW CTL VALVE [11HB] AMM 21-51-51-000-001 and AMM 21-51-51-400-001.
(2) If the fault continues:
- do the trouble shooting procedures for the pack 2 flow indication fault (Ref. TSM TASK 21-51-00-810-814).
Subtask 21-51-00-720-063-A ** ON A/C NOT FOR ALL
A. This procedure is only necessary after you do the work step Para. 4. B. (a).
Subtask 21-51-00-720-063-B ** ON A/C NOT FOR ALL - Do the procedures given in para. 3.
A. Not applicable