CPC 1 / SDAC 1+2 Interface Fault
TASK 21-51-00-810-809-A
CPC 1 / SDAC 1+2 Interface Fault
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 21-51-00-710-066-A
Subtask 21-51-00-810-062-A
[Rev.8 from Aug 2018]
2026.04.04 04:24:47 UTC
CPC 1 / SDAC 1+2 Interface Fault
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 21-31-00-710-002 | Operational Test of the Pressure Control and Monitoring |
| ASM 213103 | |
| AMM 21-31-34-000-001 | Removal of the Cabin Pressure Controller |
| AMM 21-31-34-400-001 | Installation of the Cabin Pressure Controller |
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| AMM 31-55-34-000-001 | Removal of the SDAC |
| AMM 31-55-34-400-001 | Installation of the SDAC |
Subtask 21-51-00-710-066-A
A. Do the operational test of the central warning system AMM 31-50-00-710-001.
4. Fault IsolationNOTE: Make sure that the circuit breaker 3HL is closed during the test.
Subtask 21-51-00-810-062-A
A. If the test gives the maintenance message SDAC1: NO CPCU1 DATA 11HL or SDAC1: NO CPC 1 ANALOG SIGNAL:
(2) If the test is OK:
replace the SDAC-1 [1WV1] AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
(3) If the fault continues:
replace the PRESS CONT 1 [11HL] AMM 21-31-34-000-001 and AMM 21-31-34-400-001.
Subtask 21-51-00-810-063-A - do the operational test of the pressure control and monitoring system AMM 21-31-00-710-002.
(2) If the test is OK:
replace the SDAC-1 [1WV1] AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
(3) If the fault continues:
- do a check and repair the wiring ASM 213103:
from the CPC 1 (11HL)AA/1C to the SDAC 1 (1WV1)AE/10F,
from the CPC 1 (11HL)AA/4D to the SDAC 1 (1WV1)AE/10E.
replace the PRESS CONT 1 [11HL] AMM 21-31-34-000-001 and AMM 21-31-34-400-001.
B. If the test gives the maintenance message SDAC2: NO CPCU1 DATA 11HL or SDAC2: NO CPC1 ANALOG SIGNAL:
(2) If the test is OK:
replace the SDAC-2 [1WV2] AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
(3) If the fault continues:
replace the PRESS CONT 1 [11HL] AMM 21-31-34-000-001 and AMM 21-31-34-400-001.
Subtask 21-51-00-810-066-A - do the operational test of the pressure control and monitoring system AMM 21-31-00-710-002.
(2) If the test is OK:
replace the SDAC-2 [1WV2] AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
(3) If the fault continues:
- do a check and repair the wiring ASM 213103:
from the CPC 1 (11HL)AA/1C to the SDAC 2 (1WV2)AE/10F,
from the CPC 1 (11HL)AA/4D to the SDAC 2 (1WV2)AE/10E.
replace the PRESS CONT 1 [11HL] AMM 21-31-34-000-001 and AMM 21-31-34-400-001.
C. Do the test given in Para. 3.