FCV 1 (FCU 1) Regulation/Indication Fault
TASK 21-51-00-810-807-A
FCV 1 (FCU 1) Regulation/Indication Fault
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 21-51-00-860-058-B
Subtask 21-51-00-810-075-E ** ON A/C NOT FOR ALL
Subtask 21-51-00-860-056-C
[Rev.8 from Aug 2018]
2026.04.04 04:38:52 UTC
FCV 1 (FCU 1) Regulation/Indication Fault
1. Possible Causes
- sense line connectors
- P1 FLOW SENSOR [10HB]
- P1 FLOW CTL VALVE [11HB]
- wiring
- P2 FLOW CTL VALVE [8HB]
- FLOW CTL UNIT - PACK 1 [23HB]
- FLOW CTL UNIT - PACK 2 [24HB]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 215101 | |
| AMM 21-51-11-000-001 | Removal of the Differential Pressure Sensor |
| AMM 21-51-11-400-001 | Installation of the Differential Pressure Sensor |
| AMM 21-51-51-000-001 | Removal of the Pack Flow-Control Valve/ Pack Flow-Control Unit |
| AMM 21-51-51-400-001 | Installation of the Pack Flow-Control Valve/ Pack Flow-Control Unit |
| AMM 71-00-00-710-003 | Engine Automatic Start |
| AMM 71-00-00-710-028 | Engine Shutdown |
Subtask 21-51-00-860-058-B
A. Bleed Air Supply Source from the Engines
(1) Start the engines, Ref. Para. 3.B, to supply the bleed air.
Subtask 21-51-00-860-059-A ** ON A/C NOT FOR ALL Subtask 21-51-00-860-060-A (1) Start the engines, Ref. Para. 3.B, to supply the bleed air.
C. Initial Test Set-up with Engines as Bleed Air Source Supply
(1) On the AIR COND panel 30VU:
Subtask 21-51-00-860-064-B (1) On the AIR COND panel 30VU:
- push the HOT AIR pushbutton switch to the on position (the OFF legend goes off),
- turn the COCKPIT, FWD CABIN and the AFT CABIN temperature selectors to the HOT positions and,
- make sure that the PACK 1 and the PACK 2 pushbutton switches are in the on position (the OFF legends are off).
- make sure that the pack 1 inlet pressure indication shows a minimum of 24 PSI.
NOTE: If the indication shows less than 24 PSI you must slowly adjust the throttle levers until you get the minimum indication of 24 PSI.
D. AIDS ALPHA CALL-UP menu
Subtask 21-51-00-710-062-C | ACTION | RESULT |
|---|---|
1.On one MCDU:
| On the MCDU:
|
| - press the line key adjacent to the CALL-UP PARAM indication. |
|
| - press the line key adjacent to the PARAM ALPHA CALL-UP indication. |
|
2.On the MCDU keyboard:
| On the MCDU:
|
| - press the P and F keys. | In the lower left corner of the AIDS ALPHA CALL-UP page: - PF shows. |
3.On the MCDU:
| On the AIDS ALPHA CALL-UP page: - ALPHA, SOURCE and POS.VALUE columns show. Below the ALPHA column: - the indications <PF and KG/SE show. Below the SOURCE column: - the indications PACK-1 and PACK-2 show. Below the POS.VALUE column: - the indications 1:.XX and 2:.XX show. NOTE: XX indicates the actual pack flow values (KG/SE) |
E. Test
4. Fault Isolation| ACTION | RESULT |
|---|---|
1.On the AIR COND panel 30VU:
| On the MCDU at the AIDS ALPHA CALL-UP page:
|
Subtask 21-51-00-810-075-E ** ON A/C NOT FOR ALL
A. On the MCDU at the AIDS ALPHA CALL-UP page:
Subtask 21-51-00-810-075-F ** ON A/C NOT FOR ALL - if the POS VALUE indication 1: does not agree with the flow indication parameters:
- make sure that the torque of the sense line connectors at the flow control valve and related sensor is correct. AMM 21-51-11-400-001 and AMM 21-51-51-400-001.
- replace the P1 FLOW SENSOR [10HB] AMM 21-51-11-000-001 and AMM 21-51-11-400-001.
- replace the P1 FLOW CTL VALVE [11HB] AMM 21-51-51-000-001 and AMM 21-51-51-400-001.
- do a check and repair the wiring between the:
- FCV connector (8HB-A) pin C and the PC connector (7HH-AA) pin B7.
ASM 215101.
- replace the P2 FLOW CTL VALVE [8HB] AMM 21-51-51-000-001 and AMM 21-51-51-400-001.
A. On the MCDU at the AIDS ALPHA CALL-UP page:
Subtask 21-51-00-710-063-A - if the POS VALUE indication 1: does not agree with the flow indication parameters:
- replace the FLOW CTL UNIT - PACK 1 [23HB] AMM 21-51-51-000-001 and AMM 21-51-51-400-001.
- replace the FLOW CTL UNIT - PACK 2 [24HB] AMM 21-51-51-000-001 and AMM 21-51-51-400-001.
B. Do the test as given in the Para. 3.E.
5. Close-upSubtask 21-51-00-860-056-C