Flow Selection Fault
TASK 21-51-00-810-801-A
Flow Selection Fault
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 21-51-00-710-050-A 4. Fault Isolation
Subtask 21-51-00-810-050-A ** ON A/C NOT FOR ALL
Subtask 21-51-00-860-050-A
[Rev.8 from Aug 2018]
2026.04.04 04:24:46 UTC
Flow Selection Fault
1. Possible Causes
- CTL SW-AIR COND/PACK FLOW [5HB]
- RESISTOR- [18HB]
- RESISTOR- [19HB]
- ZONE CONTROLLER [8HK]
- wiring
- CONT-AIR COND SYSTEM 1 [47HH]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 215101 | |
| AMM 21-61-00-710-001 | Operational Test of the Pack Temperature-Control System |
| AMM 21-61-34-000-002 | Removal of the Air-Conditioning System Controller |
| AMM 21-61-34-400-002 | Installation of the Air-Conditioning System Controller |
| AMM 21-63-34-000-001 | Removal of the Zone Controller |
| AMM 21-63-34-400-001 | Installation of the Zone Controller |
Subtask 21-51-00-710-050-A 4. Fault Isolation
Subtask 21-51-00-810-050-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message FLOW SEL:
(a) On the AIR COND panel 30VU:
(a) On the AIR COND panel 30VU:
Subtask 21-51-00-810-050-C ** ON A/C NOT FOR ALL - replace the CTL SW-AIR COND/PACK FLOW [5HB] .
NOTE: In this procedure:
(1) If the fault continues:- the CTL SW-AIR COND/PACK FLOW [5HB] is referred to as the PACK FLOW SELECTOR,
- for the subsequent aircraft wiring ASM 215101.
(a) On the AIR COND panel 30VU:
- do a check for continuity of the RESISTOR- [18HB] between PACK FLOW SELECTOR pins 2 and 3.
- replace the RESISTOR- [18HB] .
(a) On the AIR COND panel 30VU:
- do a check for continuity of the RESISTOR- [19HB] between PACK FLOW SELECTOR pins 3 and 4.
- replace the RESISTOR- [19HB] .
- replace the ZONE CONTROLLER [8HK] .
AMM 21-63-34-000-001 and,
AMM 21-63-34-400-001.
- do a check and repair the wiring :
from PACK FLOW SELECTOR (5HB) pin 2 to ZC 1 (8HK) pin A/15D,
from PACK FLOW SELECTOR (5HB) pin 4 to ZC 1 (8HK) pin A/14D,
from PACK FLOW SELECTOR (5HB) pin 1 to ZC 1 (8HK) pin A/13D.
A. If the test gives the maintenance message FLOW SELECTOR(5HB):
(a) On the AIR COND panel 30VU:
Subtask 21-51-00-710-051-A - replace the CTL SW-AIR COND/PACK FLOW [5HB] ASM 215101.
NOTE: In this procedure:
(1) If the fault continues:- the CTL SW-AIR COND/PACK FLOW [5HB] is referred to as the PACK FLOW SELECTOR,
- for the subsequent aircraft wiring ASM 215101.
- do a check for continuity of the RESISTOR- [18HB] between PACK FLOW SELECTOR pins 3 and 4.
- replace the RESISTOR- [18HB] .
(a) On the AIR COND panel 30VU:
- do a check for continuity of the RESISTOR- [19HB] between PACK FLOW SELECTOR pins 2 and 3.
- replace the RESISTOR- [19HB] .
- replace the CONT-AIR COND SYSTEM 1 [47HH] , AMM 21-61-34-000-002 and AMM 21-61-34-400-002.
- do a check and repair the wiring from:
- the PACK FLOW SELECTOR (5HB) to the ACSC1 (47HH).
B. Do the test as given in the Para. 3.A.
5. Close-upSubtask 21-51-00-860-050-A
A. Put the aircraft back to its initial configuration.