Aft Trim Air Pressure Regulating Valve (TAPRV) Control Circuit Fault
TASK 21-43-00-810-820-A
Aft Trim Air Pressure Regulating Valve (TAPRV) Control Circuit Fault
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 21-43-00-710-086-A ** ON A/C NOT FOR ALL
Subtask 21-43-00-810-078-A
Subtask 21-43-00-860-067-A
[Rev.8 from Aug 2018]
2026.04.04 04:24:46 UTC
Aft Trim Air Pressure Regulating Valve (TAPRV) Control Circuit Fault
1. Possible Causes
RELAY-TAPRV CLOSE (17HC) PUSHBUTTON SWITCH-CARGO HEAT/HOT AIR (16HC) - wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 214302 | |
| AMM 21-61-00-710-001 | Operational Test of the Pack Temperature-Control System |
Subtask 21-43-00-710-086-A ** ON A/C NOT FOR ALL
A. Do the operational test of the pack temperature-control system AMM 21-61-00-710-001.
Subtask 21-43-00-710-086-D ** ON A/C NOT FOR ALL 4. Fault IsolationNOTE: The ZC (8HK) also monitors the cargo compartment heating system.
Subtask 21-43-00-810-078-A
A. If the test gives the maintenance message AFT TAPRV SHUT OFF RELAY:
Subtask 21-43-00-710-087-A - do a check for the
RELAY-TAPRV CLOSE (17HC) and replace it if necessary ASM 214302.
- do a check for the
PUSHBUTTON SWITCH-CARGO HEAT/HOT AIR (16HC) and replace it if necessary ASM 214302.
- do a check and repair the wiring between:
the ACHC (10HC) AA/6A and CB (31HN) ASM 214302.
B. Do the test given in Para. 3.
5. Close-upSubtask 21-43-00-860-067-A
A. Put the aircraft back to its initial configuration.