AFT Cargo Temperature Sensor Fault
TASK 21-43-00-810-817-A
AFT Cargo Temperature Sensor Fault
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 21-43-00-710-081-A
Subtask 21-43-00-810-075-A
[Rev.8 from Aug 2018]
2026.04.04 04:24:46 UTC
AFT Cargo Temperature Sensor Fault
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 21-43-00-100-001 | Cleaning of the Cargo Compartment Duct-Temperature Sensors 3HC, 4HC and/or 13HC and the Cargo Compartment-Temperature Sensor 14HC |
Subtask 21-43-00-710-081-A
A. Not applicable.
4. Fault IsolationSubtask 21-43-00-810-075-A
A. If the AFT cargo-compartment temperature is below the selected temperature: clean the AFT CARGO DUCT SENSOR [13HC] and AFT CARGO COMP SENSOR [14HC] AMM 21-43-00-100-001