W DOC AIRBUS | TSM A320F

ACHC receives no Data from the CFDS


TASK 21-43-00-810-814-A
ACHC receives no Data from the CFDS


1. Possible Causes
  • AFT CARGO HEAT CONTROLLER [10HC]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 214302
AMM 21-43-34-000-001
Removal of the FWD Cargo Heat Controller
AMM 21-43-34-400-001
Installation of the FWD Cargo Heat Controller
AMM 21-61-00-710-001
Operational Test of the Pack Temperature-Control System
AMM 31-32-00-740-002
BITE Test of the Centralized Fault Display Interface Unit (CFDIU)
3. Fault Confirmation
Subtask 21-43-00-710-076-A
A. Do the operational test of the pack temperature-control system AMM 21-61-00-710-001.
NOTE: Make sure that the circuit breakers 2TW and 8TW are closed during the test.
4. Fault Isolation
Subtask 21-43-00-810-072-A
A. If the test gives the maintenance message NO DATA FROM CFDS:
   (1) If the operational test of the CFDS gives a different maintenance message:
  • do the related trouble shooting procedure.
   (2) If the operational test of the CFDS gives TEST OK:
     (a) If the fault continues:
  • do a check and repair the wiring of the signal ARINC 429 OUT (BUS 1) from the CFDIU (1TW) to the ACHC (10HC) ASM 214302.
Subtask 21-43-00-710-077-A
B. Do the test given in Para. 3.
5. Close-up
Subtask 21-43-00-860-063-A
A. Put the aircraft back to its initial configuration.
[Rev.8 from Aug 2018] 2026.04.04 04:24:45 UTC