W DOC AIRBUS | TSM A320F

AFT Cargo-Compartment Trim-Air Regulation Fault


TASK 21-43-00-810-808-A
AFT Cargo-Compartment Trim-Air Regulation Fault


1. Possible Causes
  • AFT CARGO TRIM AIR VALVE [12HC]
  • wiring
  • AFT CARGO HEAT CONTROLLER [10HC]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 21-43-00-740-002
Power-up (BITE) Test of the Cargo-Compartment Heating Controller
ASM 214302
AMM 21-43-34-000-002
Removal of the AFT Cargo Heat Controller
AMM 21-43-34-400-002
Installation of the AFT Cargo Heat Controller
AMM 21-43-51-000-001
Removal of the Aft Cargo-Trim Air-Valve
AMM 21-43-51-400-001
Installation of the Aft Cargo-Trim Air-Valve
3. Fault Confirmation
Subtask 21-43-00-710-057-A
A. To Confirm the Fault
   (1) Do a read out of the POST FLIGHT and/or LAST LEG REPORT.
   (2) Do the power-up (BITE) test of the cargo compartment heating controller AMM 21-43-00-740-002.
4. Fault Isolation
Subtask 21-43-00-810-057-A
A. If the conditions which follow occur:
  • the POST FLIGHT and/or the LAST LEG REPORT gives the maintenance message AFT TRIM AIR VALVE and,
    on the lower ECAM display unit COND page the AFT trim-air valve position shows amber XX:
  • replace the AFT CARGO TRIM AIR VALVE [12HC] AMM 21-43-51-000-001 and AMM 21-43-51-400-001.
   (1) If the fault continues:
  • do a check and repair the wiring ASM 214302 from:
  • the VALVE (12HC) to the ACHC (10HC) and,
  • the VALVE (12HC) to ground.
   (2) If the fault continues:
Subtask 21-43-00-710-068-A
B. Do the test as given in the Para. 3.A.
5. Close-up
Subtask 21-43-00-860-056-A
A. Put the aircraft back to its initial configuration.
[Rev.8 from Aug 2018] 2026.04.04 04:24:45 UTC