AFT Cargo-Compartment Temperature-Selector Function Fault
TASK 21-43-00-810-806-A
AFT Cargo-Compartment Temperature-Selector Function Fault
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 21-43-00-710-055-A ** ON A/C NOT FOR ALL
Subtask 21-43-00-810-055-A
Subtask 21-43-00-860-055-A
[Rev.8 from Aug 2018]
2026.04.04 04:24:45 UTC
AFT Cargo-Compartment Temperature-Selector Function Fault
1. Possible Causes
- AFT CARGO TEMP SELECTOR [15HC]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 214302 | |
| AMM 21-61-00-710-001 | Operational Test of the Pack Temperature-Control System |
Subtask 21-43-00-710-055-A ** ON A/C NOT FOR ALL
A. Do the operational test of the pack temperature-control system AMM 21-61-00-710-001.
Subtask 21-43-00-710-055-D ** ON A/C NOT FOR ALL 4. Fault IsolationNOTE: The ZC (8HK) also monitors the cargo compartment heating system.
Subtask 21-43-00-810-055-A
A. If the test gives the maintenance message AFT TEMP SELECTOR:
Subtask 21-43-00-710-067-A - replace the AFT CARGO TEMP SELECTOR [15HC] .
- do a check and repair the wiring between:
the SELECTOR (15HC) pin 4 and ACHC (10HC) AB/3A,
the SELECTOR (15HC) pin 7 and ACHC (10HC) AB/2A,
the SELECTOR (15HC) pin 2 and ACHC (10HC) AB/1A,
the SELECTOR (15HC) pin 8 and GND ASM 214302.
B. Do the test as given in the Para. 3.A.
5. Close-upSubtask 21-43-00-860-055-A
A. Put the aircraft back to its initial configuration.