W DOC AIRBUS | TSM A320F

AFT Cargo-Compartment Temperature-Sensor Fault


TASK 21-43-00-810-804-A
AFT Cargo-Compartment Temperature-Sensor Fault


1. Possible Causes
  • AFT CARGO COMP SENSOR [14HC]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 21-43-00-740-002
Power-up (BITE) Test of the Cargo-Compartment Heating Controller
ASM 214302
AMM 21-43-15-000-001
Removal of the Aft Cargo-Compartment Temperature-Sensors 13HC and 14HC
AMM 21-43-15-400-001
Installation of the Aft Cargo-Compartment Temperature-Sensors 13HC and 14HC
3. Fault Confirmation
Subtask 21-43-00-710-053-A
A. To Confirm the Fault
   (1) Do a read out of the POST FLIGHT and/or LAST LEG REPORT.
   (2) Do the power-up (BITE) test of the cargo compartment heating controller AMM 21-43-00-740-002.
4. Fault Isolation
Subtask 21-43-00-810-053-A
A. If the conditions which follow occur:
  • the POST FLIGHT and/or the LAST LEG REPORT gives the maintenance message AFT COMP TEMP SENSOR and,
    on the lower ECAM display unit COND page the AFt cargo-compartment temperature shows amber XX:
  • replace the AFT CARGO COMP SENSOR [14HC] AMM 21-43-15-000-001 and AMM 21-43-15-400-001.
   (1) If the fault continues:
  • do a check and repair the wiring ASM 214302 from:
  • the SENSOR (14HC) to the ACHC (10HC) and,
  • the SENSOR (14HC) to ground.
Subtask 21-43-00-710-065-A
B. Do the test as given in the Para. 3.A.
5. Close-up
Subtask 21-43-00-860-053-A
A. Put the aircraft back to its initial configuration.
[Rev.8 from Aug 2018] 2026.04.04 04:24:45 UTC