Cold Temperature in the Cockpit Foot Area
TASK 21-41-00-810-801-A
Cold Temperature in the Cockpit Foot Area
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 21-41-00-710-050-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 21-41-00-865-050-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:24:45 UTC
Cold Temperature in the Cockpit Foot Area
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 24-00-00-810-803-A | Circuit Breaker Tripped and/or C/B TRIPPED Warning |
| AMM 21-41-00-720-001 | Functional Test of the Foot Air-Outlet Heater |
| ASM 214101 | |
| AMM 21-41-51-000-001 | Removal of the Air Outlet Heater |
| AMM 21-41-51-400-001 | Installation of the Air Outlet Heater |
Subtask 21-41-00-710-050-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 21-41-00-865-050-A ** ON A/C NOT FOR ALL
A. Table of the circuit breakers used in this procedure:
Subtask 21-41-00-810-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 122VU | CKPT/FOOT/HEATERS | 1HE | V23 |
B. If the air blown in the cockpit is too cold, make sure that the CKPT/FOOT/HEATERS circuit breaker (1HE) is closed.
(1) If the circuit breaker is open:
(1) If the circuit breaker is open:
- Do the procedure (Ref. TSM TASK 24-00-00-810-803).
- Do a check for 115VAC at the pin A/A of the left air-outlet heater (3HE) and the pin A/A of the right air-outlet heater (4HE).
- Repair the wiring ASM 214101.
- Replace the defective HEATER-AIR OUTLET, L [3HE] or HEATER-AIR OUTLET, R [4HE] AMM 21-41-51-000-001 and AMM 21-41-51-400-001.