W DOC AIRBUS | TSM A320F

Cold Temperature in the Cockpit Foot Area


TASK 21-41-00-810-801-A
Cold Temperature in the Cockpit Foot Area


1. Possible Causes
  • wiring
  • HEATER-AIR OUTLET, L [3HE]
  • HEATER-AIR OUTLET, R [4HE]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 24-00-00-810-803-A
Circuit Breaker Tripped and/or C/B TRIPPED Warning
AMM 21-41-00-720-001
Functional Test of the Foot Air-Outlet Heater
ASM 214101
AMM 21-41-51-000-001
Removal of the Air Outlet Heater
AMM 21-41-51-400-001
Installation of the Air Outlet Heater
3. Fault Confirmation
Subtask 21-41-00-710-050-A ** ON A/C NOT FOR ALL
A. Do the functional test of the window air-outlet heater AMM 21-41-00-720-001.
4. Fault Isolation
Subtask 21-41-00-865-050-A ** ON A/C NOT FOR ALL
A. Table of the circuit breakers used in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
122VUCKPT/FOOT/HEATERS1HEV23
Subtask 21-41-00-810-050-A ** ON A/C NOT FOR ALL
B. If the air blown in the cockpit is too cold, make sure that the CKPT/FOOT/HEATERS circuit breaker (1HE) is closed.
   (1) If the circuit breaker is open:
   (2) If the circuit breaker is closed:
  • Do a check for 115VAC at the pin A/A of the left air-outlet heater (3HE) and the pin A/A of the right air-outlet heater (4HE).
     (a) If there is no 115VAC:
     (b) If there is 115VAC:
[Rev.8 from Aug 2018] 2026.04.04 04:24:45 UTC