Outflow Valve Electronic Module 2 Fault (68)


TASK 21-31-00-810-849-A
Outflow Valve Electronic Module 2 Fault (68)


1. Possible Causes
  • VALVE-OUTFLOW (10HL), ELECTRONIC MODULE 2
  • VALVE-OUTFLOW (10HL), AUTO MOTOR 2
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 21-31-00-710-002
Operational Test of the Pressure Control and Monitoring
AMM 21-31-51-000-002
Removal of the Outflow Valve (10HL) - Electronics Module 10HL-1 (10HL-2)
AMM 21-31-51-000-003
Removal of the Outflow Valve (10HL) - Auto Motor 10HL-3 (10HL-4)
AMM 21-31-51-400-002
Installation of the Outflow Valve (10HL) - Electronics Module 10HL-1 (10HL-2)
AMM 21-31-51-400-003
Installation of the Outflow Valve (10HL) - Auto Motor 10HL-3 (10HL-4)
3. Fault Confirmation
Subtask 21-31-00-710-145-A
A. Test
   (1) Do the operational test of the pressure control and monitoring system AMM 21-31-00-710-002.
4. Fault Isolation
Subtask 21-31-00-810-213-A
A. If one or both of the reports, LAST LEG REPORT, PREVIOUS LEG REPORT, and/or the test gives the maintenance message which follows,
NOTE: The electronic module 2 is connected to the electrical connector 10HL-B.
   (1) If the fault continues:
Subtask 21-31-00-710-146-A
B. Do the test as given in the Para. 3.A.