W DOC AIRBUS | TSM A320F

Cabin Pressure Controller 2 Fault (06)


TASK 21-31-00-810-847-A
Cabin Pressure Controller 2 Fault (06)


1. Possible Causes
  • VALVE-OUTFLOW (10HL), ELECTRONIC MODULE 2
  • PRESS CONT 2 [12HL]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 21-31-00-710-002
Operational Test of the Pressure Control and Monitoring
AMM 21-31-34-000-001
Removal of the Cabin Pressure Controller
AMM 21-31-34-400-001
Installation of the Cabin Pressure Controller
AMM 21-31-51-000-002
Removal of the Outflow Valve (10HL) - Electronics Module 10HL-1 (10HL-2)
AMM 21-31-51-400-002
Installation of the Outflow Valve (10HL) - Electronics Module 10HL-1 (10HL-2)
3. Fault Confirmation
Subtask 21-31-00-710-141-A
A. Test
   (1) Do the operational test of the pressure control and monitoring system AMM 21-31-00-710-002.
4. Fault Isolation
Subtask 21-31-00-810-218-A
A. If one or both of the reports, LAST LEG REPORT, PREVIOUS LEG REPORT, and/or the test gives the maintenance messages,
PRESS CONTROLLER 2 (06) and
OUTFLOW VALVE (31) source CPC2:
NOTE: The electronic module 2 is connected to the electrical connector 10HL-B.
Subtask 21-31-00-810-219-A
B. If one or both of the reports, LAST LEG REPORT, PREVIOUS LEG REPORT, and/or the test gives the maintenance messages,
PRESS CONTROLLER 1 (06) and
CONTR (30) source CPC 2:
Subtask 21-31-00-810-211-A
C. If one or both of the reports, LAST LEG REPORT, PREVIOUS LEG REPORT, and/or the test gives the maintenance message,
PRESS CONTROLLER 2 (06):
NOTE: The electronic module 2 is connected to the electrical connector 10HL-B.
Subtask 21-31-00-710-142-A
D. Do the test as given in the Para. 3.A.
[Rev.8 from Aug 2018] 2026.04.04 04:24:44 UTC