Outlow Valve Mistakenly Reported Not Open On Ground


TASK 21-31-00-810-843-A
Outlow Valve Mistakenly Reported Not Open On Ground


1. Possible Causes
  • SDAC-1 [1WV1]
  • SDAC-2 [1WV2]
  • Outflow Valve Feedback-Assembly 10HL6
  • wiring
  • PRESS CONT 1 [11HL]
  • OUTFLOW VALVE [10HL]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 21-31-00-710-002
Operational Test of the Pressure Control and Monitoring
ASM 213101
ASM 213103
AMM 21-31-34-000-001
Removal of the Cabin Pressure Controller
AMM 21-31-34-400-001
Installation of the Cabin Pressure Controller
AMM 21-31-51-000-001
Removal of the Outflow Valve (From Inside)
AMM 21-31-51-000-005
Removal of the Outflow Valve - Feedback Assembly 10HL-6
AMM 21-31-51-000-006
Removal of the Outflow Valve (From Outside)
AMM 21-31-51-400-001
Installation of the Outflow Valve (From Inside)
AMM 21-31-51-400-005
Installation of the Outflow Valve - Feedback Assembly 10HL-6
AMM 21-31-51-400-006
Installation of the Outflow Valve (From Outside)
AMM 31-55-34-000-001
Removal of the SDAC
AMM 31-55-34-400-001
Installation of the SDAC
3. Fault Confirmation
Subtask 21-31-00-710-134-A
A. Test
   (1) Do the operational test of the pressure control and monitoring system AMM 21-31-00-710-002.
4. Fault Isolation
Subtask 21-31-00-810-203-A
A. Test Results
NOTE: This procedure is only applicable for:
  • Outflow Valve Part Numbers 9023-15705-81 and previous.
   (1) If the POST FLIGHT REPORT gives the maintenance message:
   (2) If the fault continues:
   (3) If the fault continues:
   (4) If the fault continues:
  • do a check and repair the wiring between the:
  • OFV connector (10HL-D) pin F and the CPC connector (11HL-AB) pin 1D.
  • OFV connector (10HL-D) pin G and the CPC connector (11HL-AB) pin 2D.
  • OFV connector (10HL-D) pin H and the CPC connector (11HL-AB) pin 3D ASM 213101 ASM 213103.
   (5) If the fault continues:
Subtask 21-31-00-810-204-A
B. Test Results
NOTE: This procedure is only applicable for:
  • Outflow Valve Part Number 20790-01AA and onwards.
   (1) If the POST FLIGHT REPORT gives the maintenance message:
   (2) If the fault continues:
   (3) If the fault continues:
  • do a check and repair the wiring between the:
  • OFV connector (10HL-D) pin F and the CPC connector (11HL-AB) pin 1D.
  • OFV connector (10HL-D) pin G and the CPC connector (11HL-AB) pin 2D.
  • OFV connector (10HL-D) pin H and the CPC connector (11HL-AB) pin 3D ASM 213101 ASM 213103.
   (4) If the fault continues:
   (5) If the fault continues:
Subtask 21-31-00-710-135-A
C. Do the test as given in the Para. 3.A.