Outflow Valve Electronic Module 2 Fault (07), (31), (64), (65), (66), (67), (72), (76), (83), (87), (93)
TASK 21-31-00-810-834-A
Outflow Valve Electronic Module 2 Fault (07), (31), (64), (65), (66), (67), (72), (76), (83), (87), (93)
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 21-31-00-710-116-A
Subtask 21-31-00-810-185-A
[Rev.8 from Aug 2018]
2026.04.04 04:24:43 UTC
Outflow Valve Electronic Module 2 Fault (07), (31), (64), (65), (66), (67), (72), (76), (83), (87), (93)
1. Possible Causes
VALVE-OUTFLOW (10HL), ELECTRONIC MODULE 2
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 21-31-00-710-002 | Operational Test of the Pressure Control and Monitoring |
| AMM 21-31-51-000-002 | Removal of the Outflow Valve (10HL) - Electronics Module 10HL-1 (10HL-2) |
| AMM 21-31-51-400-002 | Installation of the Outflow Valve (10HL) - Electronics Module 10HL-1 (10HL-2) |
Subtask 21-31-00-710-116-A
A. Test
(1) Do the operational test of the pressure control and monitoring system AMM 21-31-00-710-002.
4. Fault Isolation(1) Do the operational test of the pressure control and monitoring system AMM 21-31-00-710-002.
Subtask 21-31-00-810-185-A
A. If one or both of the reports, LAST LEG REPORT, PREVIOUS LEG REPORT, and/or the test gives one of the maintenance messages which follow,
OUTFLOW VALVE ELEC 2 (07),
OUTFLOW VALVE ELEC 2 (64),
OUTFLOW VALVE ELEC 2 (65),
OUTFLOW VALVE ELEC 2 (66),
OUTFLOW VALVE ELEC 2 (67),
OUTFLOW VALVE ELEC 2 (72),
OUTFLOW VALVE ELEC 2 (76),
OUTFLOW VALVE ELEC 2 (83),
OUTFLOW VALVE ELEC 2 (87),
OUTFLOW VALVE ELEC 2 (93) or
OUTFLOW VALVE (31) source CPC2:
Subtask 21-31-00-710-117-A OUTFLOW VALVE ELEC 2 (07),
OUTFLOW VALVE ELEC 2 (64),
OUTFLOW VALVE ELEC 2 (65),
OUTFLOW VALVE ELEC 2 (66),
OUTFLOW VALVE ELEC 2 (67),
OUTFLOW VALVE ELEC 2 (72),
OUTFLOW VALVE ELEC 2 (76),
OUTFLOW VALVE ELEC 2 (83),
OUTFLOW VALVE ELEC 2 (87),
OUTFLOW VALVE ELEC 2 (93) or
OUTFLOW VALVE (31) source CPC2:
- replace the
VALVE-OUTFLOW (10HL), ELECTRONIC MODULE 2 (referred to as OFV (10HL)) AMM 21-31-51-000-002 and AMM 21-31-51-400-002.
NOTE: The electronic module 2 is connected to the electrical connector 10HL-B.
B. Do the test as given in the Para. 3.A.