W DOC AIRBUS | TSM A320F

Outflow Valve Electronic Module 2 Fault (52)


TASK 21-31-00-810-832-A
Outflow Valve Electronic Module 2 Fault (52)


1. Possible Causes
  • VALVE-OUTFLOW (10HL), ELECTRONIC MODULE 2
  • PRESS CONT 2 [12HL]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 21-31-00-710-002
Operational Test of the Pressure Control and Monitoring
AMM 21-31-00-760-001
Resistance Check of the Return Ground Connections - Cabin Pressure Controller (CPC) 1 (11HL) and 2 (12HL) and the Electronic Modules 10HL-1 and 10HL-2
ASM 213102
AMM 21-31-34-000-001
Removal of the Cabin Pressure Controller
AMM 21-31-34-400-001
Installation of the Cabin Pressure Controller
AMM 21-31-51-000-002
Removal of the Outflow Valve (10HL) - Electronics Module 10HL-1 (10HL-2)
AMM 21-31-51-400-002
Installation of the Outflow Valve (10HL) - Electronics Module 10HL-1 (10HL-2)
3. Fault Confirmation
Subtask 21-31-00-710-112-A
A. Test
   (1) Do the operational test of the pressure control and monitoring system AMM 21-31-00-710-002.
4. Fault Isolation
Subtask 21-31-00-810-183-A
A. Test Results
   (1) If one or both of the reports, LAST LEG REPORT, PREVIOUS LEG REPORT gives the maintenance message which follows,
  • OUTFLOW VALVE ELEC 2 (52) and/or,
  • if the test gives the maintenance message OUTFLOW VALVE ELEC 2 (52) or,
   (2) If one or both of the reports, LAST LEG REPORT, PREVIOUS LEG REPORT gives the maintenance message which follows,
NOTE: The electronic module 2 is connected to the electrical connector 10HL-B.
   (3) If the fault continues:
     (a) If the fault moves with the CPC 2:
     (b) If the fault does not move with the CPC 2:
       1 the CPC 2 connector 12HL-AC, pin 2 and on,
       2 the electronic module 2 connector 10HL-B, pin J.
NOTE: The resistance value must be smaller than 20 m.ohms.
Subtask 21-31-00-710-113-A
B. Do the test as given in the Para. 3.A.
[Rev.8 from Aug 2018] 2026.04.04 04:24:43 UTC