Outflow Valve Electronic Module 1 Fault (52)
TASK 21-31-00-810-831-A
Outflow Valve Electronic Module 1 Fault (52)
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 21-31-00-710-110-A
Subtask 21-31-00-810-182-A
[Rev.8 from Aug 2018]
2026.04.04 04:24:43 UTC
Outflow Valve Electronic Module 1 Fault (52)
1. Possible Causes
VALVE-OUTFLOW (10HL), ELECTRONIC MODULE 1 - PRESS CONT 1 [11HL]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 21-31-00-710-002 | Operational Test of the Pressure Control and Monitoring |
| AMM 21-31-00-760-001 | Resistance Check of the Return Ground Connections - Cabin Pressure Controller (CPC) 1 (11HL) and 2 (12HL) and the Electronic Modules 10HL-1 and 10HL-2 |
| ASM 213102 | |
| AMM 21-31-34-000-001 | Removal of the Cabin Pressure Controller |
| AMM 21-31-34-400-001 | Installation of the Cabin Pressure Controller |
| AMM 21-31-51-000-002 | Removal of the Outflow Valve (10HL) - Electronics Module 10HL-1 (10HL-2) |
| AMM 21-31-51-400-002 | Installation of the Outflow Valve (10HL) - Electronics Module 10HL-1 (10HL-2) |
Subtask 21-31-00-710-110-A
A. Test
(1) Do the operational test of the pressure control and monitoring system AMM 21-31-00-710-002.
4. Fault Isolation(1) Do the operational test of the pressure control and monitoring system AMM 21-31-00-710-002.
Subtask 21-31-00-810-182-A
A. Test Results
(1) If one or both of the reports, LAST LEG REPORT, PREVIOUS LEG REPORT gives the maintenance message which follows,
Subtask 21-31-00-710-111-A (1) If one or both of the reports, LAST LEG REPORT, PREVIOUS LEG REPORT gives the maintenance message which follows,
- OUTFLOW VALVE ELEC 1 (52) and/or,
- if the test gives the maintenance message OUTFLOW VALVE ELEC 1 (52) or,
- OUTFLOW VALVE ELEC 1 (52) but the test cannot confirm the fault:
- replace the
VALVE-OUTFLOW (10HL), ELECTRONIC MODULE 1 (referred to as OFV (10HL)) AMM 21-31-51-000-002 and AMM 21-31-51-400-002.
NOTE: The electronic module 1 is connected to the electrical connector 10HL-A.
(3) If the fault continues:- swap the CPC 1 (11HL) and the CPC 2 (12HL) AMM 21-31-34-000-001 and AMM 21-31-34-400-001.
- swap back the CPC 1 (11HL) and the CPC 2 (12HL) AMM 21-31-34-000-001 and AMM 21-31-34-400-001 and,
- replace the PRESS CONT 1 [11HL] AMM 21-31-34-000-001 and AMM 21-31-34-400-001.
- swap back the CPC 1 (11HL) and the CPC 2 (12HL) AMM 21-31-34-000-001 and AMM 21-31-34-400-001.
- OFV connector (10HL-A) pins R, P, N, and M to the CPC 1 connector (11HL-AA) pins 7A, 8A, 9A, and 10A ASM 213102.
- the CPC 1 connector 11HL-AC pin 2 and on,
- the electronic module 1 connector 10HL-A pin J.
NOTE: The resistance value must be smaller than 20 m.ohms.
B. Do the test as given in the Para. 3.A.