Outflow Valve Electronic Module 2 Fault (04)
TASK 21-31-00-810-830-A
Outflow Valve Electronic Module 2 Fault (04)
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 21-31-00-710-107-A
Subtask 21-31-00-810-181-A
[Rev.8 from Aug 2018]
2026.04.04 04:38:50 UTC
Outflow Valve Electronic Module 2 Fault (04)
1. Possible Causes
VALVE-OUTFLOW (10HL), ELECTRONIC MODULE 2 RELAY-AUTO MODE DRIVE SHUT OFF (17HL) - P/BSW-CABIN PRESS/MODE SEL/AUTO [14HL]
- PRESS CONT 2 [12HL]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 21-31-00-710-002 | Operational Test of the Pressure Control and Monitoring |
| AMM 21-31-00-760-001 | Resistance Check of the Return Ground Connections - Cabin Pressure Controller (CPC) 1 (11HL) and 2 (12HL) and the Electronic Modules 10HL-1 and 10HL-2 |
| ASM 213101 | |
| ASM 213102 | |
| AMM 21-31-34-000-001 | Removal of the Cabin Pressure Controller |
| AMM 21-31-34-400-001 | Installation of the Cabin Pressure Controller |
| AMM 21-31-51-000-002 | Removal of the Outflow Valve (10HL) - Electronics Module 10HL-1 (10HL-2) |
| AMM 21-31-51-400-002 | Installation of the Outflow Valve (10HL) - Electronics Module 10HL-1 (10HL-2) |
Subtask 21-31-00-710-107-A
A. Test
(1) Do the operational test of the pressure control and monitoring system AMM 21-31-00-710-002.
4. Fault Isolation(1) Do the operational test of the pressure control and monitoring system AMM 21-31-00-710-002.
Subtask 21-31-00-810-181-A
A. If one or both of the reports, LAST LEG REPORT, PREVIOUS LEG REPORT, and/or the test gives the maintenance message which follows,
Subtask 21-31-00-710-109-A - OUTFLOW VALVE ELEC 2 (04):
- replace the
VALVE-OUTFLOW (10HL), ELECTRONIC MODULE 2 (referred to as OFV (10HL)) AMM 21-31-51-000-002 and AMM 21-31-51-400-002.
NOTE: The electronic module 2 is connected to the electrical connector 10HL-B.
(1) If the fault continues:- do a check of the
RELAY-AUTO MODE DRIVE SHUT OFF (17HL) and replace it if necessary ASM 213101.
- do a check of the P/BSW-CABIN PRESS/MODE SEL/AUTO [14HL] and replace it if necessary ASM 213101.
- swap the CPC 1 (11HL) and the CPC 2 (12HL) AMM 21-31-34-000-001 and AMM 21-31-34-400-001.
- swap back the CPC 1 (11HL) and the CPC 2 (12HL) AMM 21-31-34-000-001 and AMM 21-31-34-400-001.
- replace the PRESS CONT 2 [12HL] AMM 21-31-34-000-001 and AMM 21-31-34-400-001.
- swap back the CPC 1 (11HL) and the CPC 2 (12HL) AMM 21-31-34-000-001 and AMM 21-31-34-400-001.
- OFV connector (10HL-B) pin K to the CB (2HL),
- OFV connector (10HL-B) pin L to the CPC 2 connector (12HL-AA) pin 15D,
- OFV connector (10HL-B) pins G and J to the GND,
- OFV connector (10HL-B) pins R, P, N and M to the CPC 2 connector (12HL-AA) pins 7A, 8A, 9A and 10A.
ASM 213101 and ASM 213102.
- the CPC 2 connector 12HL-AC, pin 2 and on,
- the electronic module 2 connector 10HL-B, pin J.
NOTE: The resistance value must be smaller than 20 m.ohms.
B. Do the test as given in the Para. 3.A.