Outflow Valve Electronic Module 1 Fault (04)


TASK 21-31-00-810-829-A
Outflow Valve Electronic Module 1 Fault (04)


1. Possible Causes
  • VALVE-OUTFLOW (10HL), ELECTRONIC MODULE 1
  • RELAY-AUTO MODE DRIVE SHUT OFF (17HL)
  • P/BSW-CABIN PRESS/MODE SEL/AUTO [14HL]
  • PRESS CONT 1 [11HL]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 21-31-00-710-002
Operational Test of the Pressure Control and Monitoring
AMM 21-31-00-760-001
Resistance Check of the Return Ground Connections - Cabin Pressure Controller (CPC) 1 (11HL) and 2 (12HL) and the Electronic Modules 10HL-1 and 10HL-2
ASM 213101
ASM 213102
AMM 21-31-34-000-001
Removal of the Cabin Pressure Controller
AMM 21-31-34-400-001
Installation of the Cabin Pressure Controller
AMM 21-31-51-000-002
Removal of the Outflow Valve (10HL) - Electronics Module 10HL-1 (10HL-2)
AMM 21-31-51-400-002
Installation of the Outflow Valve (10HL) - Electronics Module 10HL-1 (10HL-2)
3. Fault Confirmation
Subtask 21-31-00-710-106-A
A. Test
   (1) Do the operational test of the pressure control and monitoring system AMM 21-31-00-710-002.
4. Fault Isolation
Subtask 21-31-00-810-180-A
A. If one or both of the reports, LAST LEG REPORT, PREVIOUS LEG REPORT, and/or the test gives the maintenance message which follows,
NOTE: The electronic module 1 is connected to the electrical connector 10HL-A.
   (1) If the fault continues:
  • do a check of the RELAY-AUTO MODE DRIVE SHUT OFF (17HL) and replace it if necessary ASM 213101.
   (2) If the fault continues:
  • do a check of the P/BSW-CABIN PRESS/MODE SEL/AUTO [14HL] and replace it if necessary,
    ASM 213101.
   (3) If the fault continues:
     (a) If the fault moves with the CPC 1:
     (b) If the fault does not move with the CPC 1:
       1 Do a check and repair the wiring from the:
  • OFV connector (10HL-A) pin K to the CB (1HL),
  • OFV connector (10HL-A) pin L to the CPC 1 connector (11HL-AA) pin 15D,
  • OFV connector (10HL-A) pins G and J to the GND,
  • OFV connector (10HL-A) pins R, P, N and M to the CPC 1 connector (11HL-AA) pins 7A, 8A, 9A and 10A.
    ASM 213101 and,
    ASM 213102.
       2 Do a check of the earthing resistance at the return ground connections AMM 21-31-00-760-001 on:
  • the CPC 1 connector (11HL-AC) pin 2 and on,
  • the electronic module 1 connector (10HL-A) pin J.
NOTE: The resistance must be smaller than 20 m.ohms.
Subtask 21-31-00-710-108-A
B. Do the test as given in the Para. 3.A.