Outflow Valve does not operate in the Manual Mode


TASK 21-31-00-810-824-A
Outflow Valve does not operate in the Manual Mode


1. Possible Causes
  • MANUAL MOTOR
  • OUTFLOW VALVE [10HL]
  • P/BSW-CABIN PRESS/MODE SEL/AUTO [14HL]
  • MAN V/S CTL switch (5HL)
  • wiring
  • C/B-AIR COND/CAB PRESS/CTL/MAN [3HL]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 21-31-00-710-003
Operational Test of Manual Mode Selection and Manual Mode Pressure Control and Functional Test of Manual Mode Cabin Altitude/Outflow Valve Position Indication
ASM 213101
AMM 21-31-51-000-001
Removal of the Outflow Valve (From Inside)
AMM 21-31-51-000-004
Removal of the Outflow Valve - Manual Motor 10HL-5
AMM 21-31-51-000-006
Removal of the Outflow Valve (From Outside)
AMM 21-31-51-400-001
Installation of the Outflow Valve (From Inside)
AMM 21-31-51-400-004
Installation of the Outflow Valve - Manual Motor 10HL-5
AMM 21-31-51-400-006
Installation of the Outflow Valve (From Outside)
3. Fault Confirmation
Subtask 21-31-00-710-096-A
A. Do the operational test of the manual pressure control and monitoring AMM 21-31-00-710-003.
4. Fault Isolation
Subtask 21-31-00-810-127-A
A. If the outflow valve does not operate during the manual mode:
  • do a check for 28VDC at the outflow valve (10HL) between the pin C/A and C/B with the MAN V/S CTL switch (5HL) in the full UP and in the full DN position.
   (1) If the voltage is correct:
     (a) If the fault continues:
   (2) If the voltage is not correct:
  • do a check for 28VDC at the circuit breaker 3HL.
     (a) If the voltage is correct:
  • replace the P/BSW-CABIN PRESS/MODE SEL/AUTO [14HL] .
       1 If the fault continues:
  • replace the MAN V/S CTL switch (5HL).
       2 If the fault continues:
  • do a check and repair the wiring between:
    .the circuit breaker (3HL) and the OUTFLOW VALVE (10HL) C/A,B via the MODE SEL pushbutton switch (14HL) and the MAN V/S CTL switch (5HL),
    .the OUTFLOW VALVE (10HL) C/B to the GND via the MAN V/S CTL switch (5HL),
ASM 213101.
     (b) If the voltage is not correct:
  • replace the C/B-AIR COND/CAB PRESS/CTL/MAN [3HL] .
Subtask 21-31-00-710-097-A
B. Do the test given in Para. 3.