Outflow Valve does not operate in the Manual Mode
TASK 21-31-00-810-824-A
Outflow Valve does not operate in the Manual Mode
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 21-31-00-710-096-A 4. Fault Isolation
Subtask 21-31-00-810-127-A
[Rev.8 from Aug 2018]
2026.04.04 04:24:43 UTC
Outflow Valve does not operate in the Manual Mode
1. Possible Causes
- MANUAL MOTOR
- OUTFLOW VALVE [10HL]
- P/BSW-CABIN PRESS/MODE SEL/AUTO [14HL]
MAN V/S CTL switch (5HL) - wiring
- C/B-AIR COND/CAB PRESS/CTL/MAN [3HL]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 21-31-00-710-003 | Operational Test of Manual Mode Selection and Manual Mode Pressure Control and Functional Test of Manual Mode Cabin Altitude/Outflow Valve Position Indication |
| ASM 213101 | |
| AMM 21-31-51-000-001 | Removal of the Outflow Valve (From Inside) |
| AMM 21-31-51-000-004 | Removal of the Outflow Valve - Manual Motor 10HL-5 |
| AMM 21-31-51-000-006 | Removal of the Outflow Valve (From Outside) |
| AMM 21-31-51-400-001 | Installation of the Outflow Valve (From Inside) |
| AMM 21-31-51-400-004 | Installation of the Outflow Valve - Manual Motor 10HL-5 |
| AMM 21-31-51-400-006 | Installation of the Outflow Valve (From Outside) |
Subtask 21-31-00-710-096-A 4. Fault Isolation
Subtask 21-31-00-810-127-A
A. If the outflow valve does not operate during the manual mode:
(b) If the voltage is not correct:
Subtask 21-31-00-710-097-A - do a check for 28VDC at the outflow valve (10HL) between the pin C/A and C/B with the MAN V/S CTL switch (5HL) in the full UP and in the full DN position.
- replace the MANUAL MOTOR AMM 21-31-51-000-004 and AMM 21-31-51-400-004.
- replace the OUTFLOW VALVE [10HL] AMM 21-31-51-000-001 and AMM 21-31-51-400-001 or AMM 21-31-51-000-006 and AMM 21-31-51-400-006.
- do a check for 28VDC at the circuit breaker 3HL.
- replace the P/BSW-CABIN PRESS/MODE SEL/AUTO [14HL] .
- replace the
MAN V/S CTL switch (5HL) .
- do a check and repair the wiring between:
.the circuit breaker (3HL) and the OUTFLOW VALVE (10HL) C/A,B via the MODE SEL pushbutton switch (14HL) and the MAN V/S CTL switch (5HL),
.the OUTFLOW VALVE (10HL) C/B to the GND via the MAN V/S CTL switch (5HL),
(b) If the voltage is not correct:
- replace the C/B-AIR COND/CAB PRESS/CTL/MAN [3HL] .
B. Do the test given in Para. 3.