Outflow Valve does not operate during the Emergency Ram Air Configuration
TASK 21-31-00-810-823-A
Outflow Valve does not operate during the Emergency Ram Air Configuration
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 21-31-00-710-094-A
Subtask 21-31-00-810-126-A
[Rev.8 from Aug 2018]
2026.04.04 04:24:42 UTC
Outflow Valve does not operate during the Emergency Ram Air Configuration
1. Possible Causes
- P/BSW-AIR COND/RAM RAM AIR [4HZ]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 21-31-00-710-005 | Operational Test of Outflow Valve Partial Opening by Emergency Ram Air Switch |
| ASM 213102 |
Subtask 21-31-00-710-094-A
A. Do the operational test of the outflow opening (50 deg.) by emergency ram air switch AMM 21-31-00-710-005.
4. Fault IsolationSubtask 21-31-00-810-126-A
A. If the outflow valve does not close to approx. 50 deg:
Subtask 21-31-00-710-095-A - replace the P/BSW-AIR COND/RAM RAM AIR [4HZ] .
- do a check and repair the wiring between:
.the RAM AIR pushbutton switch (4HZ) and the CPC 1 (11HL) AA/5B,
.the RAM AIR pushbutton switch (4HZ) and the CPC 2 (12HL) AA/5B,
.the RAM AIR pushbutton switch (4HZ) and the GND,
B. Do the test given in Para. 3.