Outflow Valve does not close in the Ditching Configuration
TASK 21-31-00-810-822-A
Outflow Valve does not close in the Ditching Configuration
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 21-31-00-710-092-A
Subtask 21-31-00-810-125-A
[Rev.8 from Aug 2018]
2026.04.04 04:24:42 UTC
Outflow Valve does not close in the Ditching Configuration
1. Possible Causes
DITCHING pushbutton switch (13HL) - wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 21-31-00-710-004 | Operational Test of the Outflow Valve Closing in Ditching Configuration |
| ASM 213101 |
Subtask 21-31-00-710-092-A
A. Do the operational test of the outflow valve closing in the ditching configuration AMM 21-31-00-710-004.
4. Fault IsolationSubtask 21-31-00-810-125-A
A. If the outflow valve does not close:
Subtask 21-31-00-710-093-A - replace the
DITCHING pushbutton switch (13HL) .
- do a check and repair the wiring between:
.the DITCHING pushbutton switch (13HL) and the CPC 1 (11HL) AB/4B,
.the DITCHING pushbutton switch (13HL) and the CPC 2 (12HL) AB/4B,
.the DITCHING pushbutton switch (13HL) and the GND.
B. Do the test given in Para. 3.