Outflow Valve does not close in the Ditching Configuration


TASK 21-31-00-810-822-A
Outflow Valve does not close in the Ditching Configuration


1. Possible Causes
  • DITCHING pushbutton switch (13HL)
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 21-31-00-710-004
Operational Test of the Outflow Valve Closing in Ditching Configuration
ASM 213101
3. Fault Confirmation
Subtask 21-31-00-710-092-A
A. Do the operational test of the outflow valve closing in the ditching configuration AMM 21-31-00-710-004.
4. Fault Isolation
Subtask 21-31-00-810-125-A
A. If the outflow valve does not close:
  • replace the DITCHING pushbutton switch (13HL).
   (1) If the fault continues:
  • do a check and repair the wiring between:
    .the DITCHING pushbutton switch (13HL) and the CPC 1 (11HL) AB/4B,
    .the DITCHING pushbutton switch (13HL) and the CPC 2 (12HL) AB/4B,
    .the DITCHING pushbutton switch (13HL) and the GND.
ASM 213101.
Subtask 21-31-00-710-093-A
B. Do the test given in Para. 3.