W DOC AIRBUS | TSM A320F

DMU receives no Data from the CPC 1


TASK 21-31-00-810-818-A
DMU receives no Data from the CPC 1


1. Possible Causes
  • DMU [1TV]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 21-31-00-710-002
Operational Test of the Pressure Control and Monitoring
ASM 213103
AMM 31-36-00-710-001
Test of the DMU
AMM 31-36-34-000-001
Removal of the Data Management Unit (DMU)
AMM 31-36-34-400-001
Installation of the Data Management Unit (DMU)
3. Fault Confirmation
Subtask 21-31-00-710-084-A
A. Do the Test of the DMU AMM 31-36-00-710-001.
NOTE: Make sure that the circuit breakers 1HL, 2HL and 3HL are closed during the test.
4. Fault Isolation
Subtask 21-31-00-810-111-A
A. If the test gives the maintenance message NO PRESS CONTROL 1 DATA:
   (1) If the fault continues:
   (2) If the fault continues:
  • do a check and repair the wiring of the signal ARINC 429 OUT (BUS 1.1) from the CPC 1 (11HL) to the DMU (1TV) ASM 213103 and ASM 213103.
Subtask 21-31-00-710-085-A
B. Do the test given in Para. 3.
5. Close-up
Subtask 21-31-00-860-067-A
A. Put the aircraft back to its initial configuration.
[Rev.8 from Aug 2018] 2026.04.04 04:24:42 UTC