Cabin Pressure Controller 2 Fault
TASK 21-31-00-810-806-A
Cabin Pressure Controller 2 Fault
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 21-31-00-710-055-A
Subtask 21-31-00-810-099-A
[Rev.8 from Aug 2018]
2026.04.04 04:24:41 UTC
Cabin Pressure Controller 2 Fault
1. Possible Causes
- PRESS CONT 2 [12HL]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 21-31-00-710-002 | Operational Test of the Pressure Control and Monitoring |
| AMM 21-31-34-000-001 | Removal of the Cabin Pressure Controller |
| AMM 21-31-34-400-001 | Installation of the Cabin Pressure Controller |
Subtask 21-31-00-710-055-A
A. Test
(1) Do the operational test of the pressure control and monitoring system AMM 21-31-00-710-002.
4. Fault Isolation(1) Do the operational test of the pressure control and monitoring system AMM 21-31-00-710-002.
Subtask 21-31-00-810-099-A
A. If one or more of these reports, LAST LEG REPORT, PREVIOUS LEG REPORT and CLASS 3 REPORT and/or the test gives one of the maintenance messages which follow:
Subtask 21-31-00-710-064-A - PRESS CONTROLLER 2 (00) or,
- PRESS CONTROLLER 2 (01) or,
- PRESS CONTROLLER 2 (08) or,
- PRESS CONTROLLER 2 (12) or,
- PRESS CONTROLLER 2 (13) or,
- PRESS CONTROLLER 2 (18) or,
- PRESS CONTROLLER 2 (22) or,
- PRESS CONTROLLER 2 (34) or,
- PRESS CONTROLLER 2 (36) or,
- PRESS CONTROLLER 2 (37) or,
- PRESS CONTROLLER 2 (38) or,
- PRESS CONTROLLER 2 (39) or,
- PRESS CONTROLLER 2 (40) or,
- PRESS CONTROLLER 2 (41) or,
- PRESS CONTROLLER 2 (42) or,
- PRESS CONTROLLER 2 (43) or,
- PRESS CONTROLLER 2 (45) or,
- PRESS CONTROLLER 2 (46) or,
- PRESS CONTROLLER 2 (47) or,
- PRESS CONTROLLER 2 (48) or,
- PRESS CONTROLLER 2 (49) or,
- PRESS CONTROLLER 2 (53) or,
- PRESS CONTROLLER 2 (58) or,
- PRESS CONTROLLER 2 (61),
- replace the PRESS CONT 2 [12HL] AMM 21-31-34-000-001 and AMM 21-31-34-400-001.
B. Do the test as given in the Para. 3.A.