W DOC AIRBUS | TSM A320F

Outflow Valve Feedback Assembly Fault (CPC 1)


TASK 21-31-00-810-805-A
Outflow Valve Feedback Assembly Fault (CPC 1)


1. Possible Causes
  • VALVE-OUTFLOW (10HL), FEEDBACK ASSEMBLY
  • VALVE-OUTFLOW (10HL), ELECTRONIC MODULE 1
  • wiring
  • OUTFLOW VALVE [10HL]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 21-31-00-710-002
Operational Test of the Pressure Control and Monitoring
ASM 213101
ASM 213103
AMM 21-31-51-000-001
Removal of the Outflow Valve (From Inside)
AMM 21-31-51-000-002
Removal of the Outflow Valve (10HL) - Electronics Module 10HL-1 (10HL-2)
AMM 21-31-51-000-005
Removal of the Outflow Valve - Feedback Assembly 10HL-6
AMM 21-31-51-400-001
Installation of the Outflow Valve (From Inside)
AMM 21-31-51-400-002
Installation of the Outflow Valve (10HL) - Electronics Module 10HL-1 (10HL-2)
AMM 21-31-51-400-005
Installation of the Outflow Valve - Feedback Assembly 10HL-6
3. Fault Confirmation
Subtask 21-31-00-710-054-A
A. Test
   (1) Do the operational test of the pressure control and monitoring system AMM 21-31-00-710-002.
NOTE: Before you do the fault isolation procedure you must make a note of:
  • the part number of the OFV which is installed in the aircraft.
4. Fault Isolation
Subtask 21-31-00-810-196-A
A. Test Results
NOTE: This procedure is only applicable for:
  • Outflow Valve Part Numbers 9023-15703-81 and previous.
   (1) If one or both of the reports, LAST LEG REPORT, PREVIOUS LEG REPORT and/or the test gives the maintenance message,
   (2) If the fault continues:
NOTE: The electronic module 1 is connected to the electrical connector 10HL-A.
   (3) If the fault continues:
  • do a check and repair the wiring between the:
  • OFV connector (10HL-D) pins A, B, C, D and E and the OFV connector (10HL-A) pins A, B, C, E and F,
  • OFV connector (10HL-D) pin J and GND ASM 213101 and ASM 213103.
Subtask 21-31-00-810-199-A
B. Test Results
NOTE: This procedure is only applicable for:
  • Outflow Valve Part Number 20790-01AA and onwards.
   (1) If one or both of the reports, LAST LEG REPORT, PREVIOUS LEG REPORT and/or the test gives the maintenance message,
   (2) If the fault continues:
  • do a check and repair the wiring between the:
  • OFV connector (10HL-D) pins A, B, C, D and E and the OFV connector (10HL-A) pins A, B, C, E and F,
  • OFV connector (10HL-D) pin J and GND ASM 213101 and ASM 213103.
Subtask 21-31-00-710-062-A
C. Do the test as given in the Para. 3.A.
[Rev.8 from Aug 2018] 2026.04.04 04:38:51 UTC