Manual Mode - CPC Fault
TASK 21-31-00-810-802-A
Manual Mode - CPC Fault
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 21-31-00-710-051-A 4. Fault Isolation
Subtask 21-31-00-810-052-A
Subtask 21-31-00-720-050-A
[Rev.8 from Aug 2018]
2026.04.04 04:24:41 UTC
Manual Mode - CPC Fault
1. Possible Causes
CONNECTOR (11HL-AB) CONNECTOR (12HL-AB) CONNECTOR (14HL-A) - PRESS CONT 1 [11HL]
- PRESS CONT 2 [12HL]
- P/BSW-CABIN PRESS/MODE SEL/AUTO [14HL]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 21-31-00-710-002 | Operational Test of the Pressure Control and Monitoring |
| ASM 213101 | |
| AMM 21-31-34-000-001 | Removal of the Cabin Pressure Controller |
| AMM 21-31-34-400-001 | Installation of the Cabin Pressure Controller |
Subtask 21-31-00-710-051-A 4. Fault Isolation
Subtask 21-31-00-810-052-A
A. If, when the MAN mode is selected, on the upper ECAM DU the warning CAB PR SYS 1+2 FAULT shows and,
on the MODE SEL p/b switch the FAULT legend comes on do a:
(1) Wiring Continuity and Ground check ASM 213101
(a) Do a check for continuity of the electrical wiring at,
5. Close-upon the MODE SEL p/b switch the FAULT legend comes on do a:
(1) Wiring Continuity and Ground check ASM 213101
(a) Do a check for continuity of the electrical wiring at,
- the
CONNECTOR (11HL-AB) pin 3B, - the
CONNECTOR (12HL-AB) pin 3B and, - the
CONNECTOR (14HL-A) pin C1.
- repair as required.
- the CONNECTOR (11HL-AB) pin 3B,
- the CONNECTOR (12HL-AB) pin 3B and,
- the CONNECTOR (14HL-A) pin C1.
NOTE: A ground condition should not be found.
(2) If a ground condition is found at any of the pins checked in Para. 4 A. (1): - replace the related,
PRESS CONT 1 [11HL] or PRESS CONT 2 [12HL] , AMM 21-31-34-000-001 and AMM 21-31-34-400-001 or,
the P/BSW-CABIN PRESS/MODE SEL/AUTO [14HL] ASM 213101.
Subtask 21-31-00-720-050-A
A. Do the test as in Para. 3. A.