W DOC AIRBUS | TSM A320F

Manual Mode - CPC Fault


TASK 21-31-00-810-802-A
Manual Mode - CPC Fault


1. Possible Causes
  • CONNECTOR (11HL-AB)
  • CONNECTOR (12HL-AB)
  • CONNECTOR (14HL-A)
  • PRESS CONT 1 [11HL]
  • PRESS CONT 2 [12HL]
  • P/BSW-CABIN PRESS/MODE SEL/AUTO [14HL]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 21-31-00-710-002
Operational Test of the Pressure Control and Monitoring
ASM 213101
AMM 21-31-34-000-001
Removal of the Cabin Pressure Controller
AMM 21-31-34-400-001
Installation of the Cabin Pressure Controller
3. Fault Confirmation
Subtask 21-31-00-710-051-A
A. Do the operational test of the pressure control and monitoring system AMM 21-31-00-710-002.
4. Fault Isolation
Subtask 21-31-00-810-052-A
A. If, when the MAN mode is selected, on the upper ECAM DU the warning CAB PR SYS 1+2 FAULT shows and,
on the MODE SEL p/b switch the FAULT legend comes on do a:
   (1) Wiring Continuity and Ground check ASM 213101
     (a) Do a check for continuity of the electrical wiring at,
  • the CONNECTOR (11HL-AB) pin 3B,
  • the CONNECTOR (12HL-AB) pin 3B and,
  • the CONNECTOR (14HL-A) pin C1.
     (b) If the wiring is not correct:
  • repair as required.
     (c) If the wiring is correct do a check for ground at,
  • the CONNECTOR (11HL-AB) pin 3B,
  • the CONNECTOR (12HL-AB) pin 3B and,
  • the CONNECTOR (14HL-A) pin C1.
NOTE: A ground condition should not be found.
   (2) If a ground condition is found at any of the pins checked in Para. 4 A. (1):
5. Close-up
Subtask 21-31-00-720-050-A
A. Do the test as in Para. 3. A.
[Rev.8 from Aug 2018] 2026.04.04 04:24:41 UTC