Cabin Pressure Controller 1 Fault
TASK 21-31-00-810-801-A
Cabin Pressure Controller 1 Fault
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 21-31-00-710-050-A
Subtask 21-31-00-810-128-A
[Rev.8 from Aug 2018]
2026.04.04 04:38:49 UTC
Cabin Pressure Controller 1 Fault
1. Possible Causes
- PRESS CONT 1 [11HL]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 21-31-00-710-002 | Operational Test of the Pressure Control and Monitoring |
| AMM 21-31-34-000-001 | Removal of the Cabin Pressure Controller |
| AMM 21-31-34-400-001 | Installation of the Cabin Pressure Controller |
Subtask 21-31-00-710-050-A
A. Test
(1) Do the operational test of the pressure control and monitoring system AMM 21-31-00-710-002.
4. Fault Isolation(1) Do the operational test of the pressure control and monitoring system AMM 21-31-00-710-002.
Subtask 21-31-00-810-128-A
A. If one or more of these reports, LAST LEG REPORT, PREVIOUS LEG REPORT and CLASS 3 REPORT and/or the test gives one of the maintenance messages which follow:
Subtask 21-31-00-710-058-A - PRESS CONTROLLER 1 (00) or,
- PRESS CONTROLLER 1 (01) or,
- PRESS CONTROLLER 1 (08) or,
- PRESS CONTROLLER 1 (12) or,
- PRESS CONTROLLER 1 (13) or,
- PRESS CONTROLLER 1 (18) or,
- PRESS CONTROLLER 1 (22) or,
- PRESS CONTROLLER 1 (34) or,
- PRESS CONTROLLER 1 (36) or,
- PRESS CONTROLLER 1 (37) or,
- PRESS CONTROLLER 1 (38) or,
- PRESS CONTROLLER 1 (39) or,
- PRESS CONTROLLER 1 (40) or,
- PRESS CONTROLLER 1 (41) or,
- PRESS CONTROLLER 1 (42) or,
- PRESS CONTROLLER 1 (43) or,
- PRESS CONTROLLER 1 (45) or,
- PRESS CONTROLLER 1 (46) or,
- PRESS CONTROLLER 1 (47) or,
- PRESS CONTROLLER 1 (48) or,
- PRESS CONTROLLER 1 (49) or,
- PRESS CONTROLLER 1 (53) or,
- PRESS CONTROLLER 1 (58) or,
- PRESS CONTROLLER 1 (61),
- replace the PRESS CONT 1 [11HL] AMM 21-31-34-000-001 and AMM 21-31-34-400-001.
B. Do the test as given in the Para. 3.A.