AFT Cargo-Compartment Fan Fault
TASK 21-28-00-810-805-A
AFT Cargo-Compartment Fan Fault
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 21-28-00-710-053-B
Subtask 21-28-00-810-057-A ** ON A/C NOT FOR ALL
Subtask 21-28-00-860-053-A
[Rev.8 from Aug 2018]
2026.04.04 04:24:40 UTC
AFT Cargo-Compartment Fan Fault
1. Possible Causes
- AFT CARGO FAN [35HN]
- ZONE CONTROLLER [8HK]
- wiring
- CARGO VENT CONTROLLER [10HN]
- CONT-AIR COND SYSTEM 1 [47HH]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 212802 | |
| AMM 21-28-34-000-001 | Removal of the Ventilation Controller |
| AMM 21-28-34-400-001 | Installation of the Ventilation Controller |
| AMM 21-28-54-000-001 | Removal of the Aft Cargo-Compartment Ventilation Extraction-Fan |
| AMM 21-28-54-400-001 | Installation of the Aft Cargo-Compartment Ventilation Extraction-Fan |
| AMM 21-61-00-710-001 | Operational Test of the Pack Temperature-Control System |
| ASM 216101 | |
| AMM 21-61-34-000-002 | Removal of the Air-Conditioning System Controller |
| AMM 21-61-34-400-002 | Installation of the Air-Conditioning System Controller |
| ASM 216301 | |
| AMM 21-63-34-000-001 | Removal of the Zone Controller |
| AMM 21-63-34-400-001 | Installation of the Zone Controller |
Subtask 21-28-00-710-053-B
A. Test
(1) Make sure that the CB's 30HN and 31HN are closed.
(2) Do the operational test of the pack temperature-control system
AMM 21-61-00-710-001.
4. Fault Isolation(1) Make sure that the CB's 30HN and 31HN are closed.
(2) Do the operational test of the pack temperature-control system
AMM 21-61-00-710-001.
Subtask 21-28-00-810-057-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message AFT CARGO FAN OR SPLY:
(a) Do a check and repair the wiring ASM 216301 from:
Subtask 21-28-00-810-057-D ** ON A/C NOT FOR ALL - replace the AFT CARGO FAN [35HN] AMM 21-28-54-000-001 and, AMM 21-28-54-400-001.
- replace the ZONE CONTROLLER [8HK] AMM 21-63-34-000-001 and, AMM 21-63-34-400-001.
(a) Do a check and repair the wiring ASM 216301 from:
- the ZC (8HK) to the VC (10HN).
- replace the CARGO VENT CONTROLLER [10HN] AMM 21-28-34-000-001 and, AMM 21-28-34-400-001.
- do a check and repair the wiring ASM 212802 and ASM 216101 from:
- the VC (10HN) to the ZC (8HK),
- the VC (10HN) to the FAN (35HN),
- the VC (10HN) to ground,
- the VC (10HN) to the CB (30HN),
- the VC (10HN) to the CB (31HN) and,
- the FAN (35HN) to ground.
A. If the test gives the maintenance message AFT CARGO FAN OR SPLY(35HN):
(a) Do a check and repair the wiring ASM 216301 from:
Subtask 21-28-00-710-062-A - replace the AFT CARGO FAN [35HN] AMM 21-28-54-000-001 and, AMM 21-28-54-400-001.
- replace the CONT-AIR COND SYSTEM 1 [47HH] , AMM 21-61-34-000-002 and AMM 21-61-34-400-002.
(a) Do a check and repair the wiring ASM 216301 from:
- the ACSC1 (47HH) to the VC (10HN).
- replace the CARGO VENT CONTROLLER [10HN] AMM 21-28-34-000-001 and, AMM 21-28-34-400-001.
- do a check and repair the wiring ASM 212802 and ASM 216101 from:
- the VC (10HN) to the ACSC1 (47HH),
- the VC (10HN) to the FAN (35HN),
- the VC (10HN) to ground,
- the VC (10HN) to the CB (30HN),
- the VC (10HN) to the CB (31HN) and,
- the FAN (35HN) to ground.
B. Do the test as given in the Para. 3.A.
5. Close-upSubtask 21-28-00-860-053-A
A. Put the aircraft back to its initial configuration.