W DOC AIRBUS | TSM A320F

FWD Cargo-Compartment Fan Fault


TASK 21-28-00-810-803-A
FWD Cargo-Compartment Fan Fault


1. Possible Causes
  • ZONE CONTROLLER [8HK]
  • wiring
  • CONT-AIR COND SYSTEM 1 [47HH]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 21-61-00-710-001
Operational Test of the Pack Temperature-Control System
AMM 21-61-34-000-002
Removal of the Air-Conditioning System Controller
AMM 21-61-34-400-002
Installation of the Air-Conditioning System Controller
ASM 216301
ASM 216303
AMM 21-63-34-000-001
Removal of the Zone Controller
AMM 21-63-34-400-001
Installation of the Zone Controller
3. Fault Confirmation
Subtask 21-28-00-710-052-A
A. Test
NOTE: This fault isolation procedure is applicable although the FWD cargo-compartment ventilation system is not installed.
   (1) Do the operational test of the pack temperature-control system
AMM 21-61-00-710-001.
4. Fault Isolation
Subtask 21-28-00-810-066-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message FWD CARGO FAN OR SPLY:
   (1) If the fault continues:
     (a) Remove the ZONE CONTROLLER [8HK] .
     (b) Do a check and repair the wiring between:
     (c) Install the ZONE CONTROLLER [8HK] .
Subtask 21-28-00-810-066-C ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message FWD CARGO FAN OR SPLY:
   (1) If the fault continues:
     (a) Remove the CONT-AIR COND SYSTEM 1 [47HH] .
     (b) Do a check and repair the wiring between:
     (c) Install the CONT-AIR COND SYSTEM 1 [47HH] .
Subtask 21-28-00-710-061-A
B. Do the test as given in the Para. 3.A.
5. Close-up
Subtask 21-28-00-860-052-A
A. Put the aircraft back to its initial configuration.
[Rev.8 from Aug 2018] 2026.04.04 04:24:40 UTC