AFT Cargo-Compartment Isolation Valve(s) Fault
TASK 21-28-00-810-802-A
AFT Cargo-Compartment Isolation Valve(s) Fault
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 21-28-00-710-051-A
Subtask 21-28-00-810-052-A
Subtask 21-28-00-860-051-A
[Rev.8 from Aug 2018]
2026.04.04 04:39:08 UTC
AFT Cargo-Compartment Isolation Valve(s) Fault
1. Possible Causes
- ISOL VALVE AFT CARGO OUTLET [33HN]
- CARGO VENT CONTROLLER [10HN]
- wiring
- ISOL VALVE AFT CARGO INLET [34HN]
- P/BSW-CARGO SMOKE/TEST [13WH]
PUSHBUTTON SWITCH-CARGO VENT/AFT ISOL VALVE (36HN) - PUSHBUTTON SWITCH-TEST [16WH]
- BOARD-ANN LT TEST & INTFC [8LP]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 21-28-00-710-006 | Operational Test of the AFT Cargo-Compartment Ventilation-System |
| ASM 212802 | |
| AMM 21-28-34-000-001 | Removal of the Ventilation Controller |
| AMM 21-28-34-400-001 | Installation of the Ventilation Controller |
| AMM 21-28-52-000-001 | Removal of the AFT Cargo-Compartment Ventilation Isolation-Valves |
| AMM 21-28-52-400-001 | Installation of the AFT Cargo-Compartment Ventilation Isolation-Valves |
| AMM 26-17-00-710-001 | Operational Test of the Lavatory Smoke-Detection System |
| AMM 32-69-00-740-001 | BITE Check of Landing-Gear Control Interface-Unit (LGCIU) With Use of MCDU to Ensure that Continuous BITE is Operative |
Subtask 21-28-00-710-051-A
A. Do the operational test of the AFT cargo-compartment ventilation-system AMM 21-28-00-710-006.
4. Fault IsolationNOTE: You must visually monitor the inlet and outlet isolation valves in the AFT cargo compartment during the test.
Subtask 21-28-00-810-052-A
A. If the isolation valve (33HN) does not operate and the FAULT legend on the pushbutton switch AFT ISOL VALVE, which is installed on the panel 22VU, comes on:
Subtask 21-28-00-810-053-A - make sure that the grids and the duct are clean.
- do a check of the valve for damage AMM 21-28-52-000-001 and AMM 21-28-52-400-001.
- replace the ISOL VALVE AFT CARGO OUTLET [33HN] (referred to as VALVE (33HN)) AMM 21-28-52-000-001 and AMM 21-28-52-400-001.
- replace the CARGO VENT CONTROLLER [10HN] AMM 21-28-34-000-001 and AMM 21-28-34-400-001.
- do a check and repair the wiring between:
VALVE (33HN) connector A/E and VC (10HN) connector B/X,
VALVE (33HN) connector A/B and VC (10HN) connector B/Y,
VALVE (33HN) connector A/A and VC (10HN) connector B/<B,
VALVE (33HN) connector A/D and VC (10HN) connector B/<A,
VALVE (33HN) connector A/F and GND,
VALVE (33HN) connector A/C and GND ASM 212802.
B. If the isolation valve (34HN) does not operate and the FAULT legend on the pushbutton switch AFT ISOL VALVE, which is installed on the panel 22VU, comes on:
Subtask 21-28-00-810-056-A ** ON A/C NOT FOR ALL - make sure that the grid and the duct are clean.
- do a check of the valve for damage AMM 21-28-52-000-001 and AMM 21-28-52-400-001.
- replace the ISOL VALVE AFT CARGO INLET [34HN] (referred to as VALVE (34HN)) AMM 21-28-52-000-001 and AMM 21-28-52-400-001.
- replace the CARGO VENT CONTROLLER [10HN] AMM 21-28-34-000-001 and AMM 21-28-34-400-001.
- do a check and repair the wiring between:
VALVE (34HN) connector A/E and VC (10HN) connector B/<C,
VALVE (34HN) connector A/B and VC (10HN) connector B/<D,
VALVE (34HN) connector A/A and VC (10HN) connector B/<F,
VALVE (34HN) connector A/D and VC (10HN) connector B/<E,
VALVE (34HN) connector A/F and GND,
VALVE (34HN) connector A/C and GND ASM 212802.
C. If the two isolation valves (33HN) and (34HN) do not operate but the FAULT legend on the pushbutton switch AFT ISOL VALVE, which is installed on the panel 22VU, does not come on:
(b) If the fault continues:
Subtask 21-28-00-810-056-D ** ON A/C NOT FOR ALL - do a check for a ground signal at the VC (10HN) connector B/H ASM 212802.
- do a check of the P/BSW-CARGO SMOKE/TEST [13WH] and replace it if necessary ASM 212802.
- do a check and repair the wiring if necessary between:
VC (10HN) connector B/H and SW (13WH) connector A/11,
SW (13WH) connector A12 and GND ASM 212802.
- do a check for a ground signal at the VC (10HN) connector B/K ASM 212802.
- do the operational test of the lavatory smoke-detection sytem AMM 26-17-00-710-001.
(b) If the fault continues:
- do a check and repair the wiring if necessary between:
VC (10HN) connector B/K and SDCU (10WQ) connector A/3C,
SDCU (10WQ) connector A/3D and GND ASM 212802.
- do a check for a ground signal at the VC (10HN) connector B/T ASM 212802.
- do a check of the
PUSHBUTTON SWITCH-CARGO VENT/AFT ISOL VALVE (36HN) and replace it if necessary ASM 212802.
- do a check and repair the wiring if necessary between:
VC (10HN) connector B/T and SW (36HN) connector A/A2,
SW (36HN) connector A/A3 and GND ASM 212802.
- replace the CARGO VENT CONTROLLER [10HN] AMM 21-28-34-000-001 and AMM 21-28-34-400-001.
- do a check and repair the wiring between:
- VC (10HN) connector B/L and CB (31HN),
- VC (10HN) connector B/M and GND,
- VC (10HN) connector B/N and GND,
- VC (10HN) connector B/Z and GND ASM 212802.
C. If the two isolation valves (33HN) and (34HN) do not operate but the FAULT legend on the pushbutton switch AFT ISOL VALVE, which is installed on the panel 22VU, does not come on:
(b) If the fault continues:
Subtask 21-28-00-810-064-A - do a check for a ground signal at the VC (10HN) connector B/H ASM 212802.
- do a check of the PUSHBUTTON SWITCH-TEST [16WH] and replace it if necessary ASM 212802.
- do a check and repair the wiring if necessary between:
VC (10HN) connector B/H and SW (16WH) connector A/E1,
SW (16WH) connector A/E3 and GND ASM 212802.
- do a check for a ground signal at the VC (10HN) connector B/K ASM 212802.
- do the operational test of the lavatory smoke-detection sytem AMM 26-17-00-710-001.
(b) If the fault continues:
- do a check and repair the wiring if necessary between:
VC (10HN) connector B/K and SDCU (10WQ) connector A/3C,
SDCU (10WQ) connector A/3D and GND ASM 212802.
- do a check for a ground signal at the VC (10HN) connector B/T ASM 212802.
- do a check of the
PUSHBUTTON SWITCH-CARGO VENT/AFT ISOL VALVE (36HN) and replace it if necessary ASM 212802.
- do a check and repair the wiring if necessary between:
VC (10HN) connector B/T and SW (36HN) connector A/A2,
SW (36HN) connector A/A3 and GND ASM 212802.
- replace the CARGO VENT CONTROLLER [10HN] AMM 21-28-34-000-001 and AMM 21-28-34-400-001.
- do a check and repair the wiring between:
- VC (10HN) connector B/L and CB (31HN),
- VC (10HN) connector B/M and GND,
- VC (10HN) connector B/N and GND,
- VC (10HN) connector B/Z and GND ASM 212802.
D. If the two isolation valves (33HN) and (34HN) operate but the FAULT legend on the pushbutton switch AFT ISOL VALVE, which is installed on the panel 22VU, comes on:
(2) If the fault continues:
Subtask 21-28-00-710-060-A - do the bite test of the landing gear AMM 32-69-00-740-001.
(2) If the fault continues:
- do a check of the BOARD-ANN LT TEST & INTFC [8LP] and replace it if necessary ASM 212802.
- replace the CARGO VENT CONTROLLER [10HN] AMM 21-28-34-000-001 and AMM 21-28-34-400-001.
- do a check and repair the wiring between:
VC (10HN) connector B/S and RELAY (8LP) connector A/14,
RELAY (8LP) connector A/15 and CB (31HN),
RELAY (8LP) connector A/13 and SW (36HN) connector A/7,
RELAY (8LP) connector A/41 and GND ASM 212802.
E. Do the test as given in the Para. 3.A.
5. Close-upSubtask 21-28-00-860-051-A
A. Put the aircraft back to its initial configuration.