W DOC AIRBUS | TSM A320F

Extract Fan Inoperative due to a Failure of the AEVC


TASK 21-26-00-810-844-A
Extract Fan Inoperative due to a Failure of the AEVC


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 21-26-00-710-001
Operational Check of the Avionics Equipment Ventilation-System via MCDU
AMM 21-26-00-710-008
Operational Test to Read the CFDS for CLASS 3 Faults of the AEVC
AMM 21-26-00-710-009
Operational Test to Read the CFDS for LAST LEG REPORT of the AEVC
ASM 212602
AMM 21-26-34-000-001
Removal of the Avionics Equipment Ventilation Computer (AEVC)
AMM 21-26-34-400-001
Installation of the Avionics Equipment Ventilation Computer (AEVC)
3. Fault Confirmation
Subtask 21-26-00-865-073-A
A. Table of the circuit breakers used in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
122VUAIR COND/AVNCS/VENT/MONG3HQY17
Subtask 21-26-00-710-115-A
B. Test
   (1) Do the reset of the AEVC (10HQ).
     (a) Open the circuit breaker AIR COND/AVNCS/VENT/MONG (3HQ).
     (b) Wait for five seconds.
     (c) Close the circuit breaker AIR COND/AVNCS/VENT/MONG (3HQ).
   (2) Do the operational test of the avionics equipment ventilation from the Multipurpose Control and Display Unit (MCDU) AMM 21-26-00-710-001.
   (3) Read the LAST LEG REPORT of the AEVC AMM 21-26-00-710-009.
   (4) Read the CLASS 3 faults of the AEVC AMM 21-26-00-710-008.
4. Fault Isolation
Subtask 21-26-00-810-094-A
A. If the test gives the maintenance message AEVC:
   (1) If the fault continues:
  • Do a check and repair the wiring ASM 212602 between:
    . Pin 2 of the AIR COND/AVNCS/VENT/CTL circuit breaker (6HQ) and pin A/E of the avionics-ventilation extract fan (18HQ)
    . Pin A/D of the avionics-ventilation extract fan (18HQ) and pin X of the avionics-ventilation extract-fan contactor (7HQ)
    . Pin Z of the avionics-ventilation extract fan contactor (7HQ) and pin AA/9A of the AEVC (10HQ).
Subtask 21-26-00-710-127-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:24:39 UTC