Failure of the AEVC Power Supplies or Inadvertent Pressure Switch Detection
TASK 21-26-00-810-841-A
Failure of the AEVC Power Supplies or Inadvertent Pressure Switch Detection
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 21-26-00-865-078-A
Subtask 21-26-00-810-098-A
[Rev.8 from Aug 2018]
2026.04.04 04:24:39 UTC
Failure of the AEVC Power Supplies or Inadvertent Pressure Switch Detection
1. Possible Causes
P/BSW-VENTILATION/BLOWER (13HQ) - wiring
- C/B-AIR COND/AVNCS VENT/CTL [5HQ]
- C/B-AIR COND/AVNCS VENT/CTL [6HQ]
P/BSW-VENTILATION/EXTRACT (14HQ) P/BSW-CABIN PRESS/DITCHING (13HL) - AEVC [10HQ]
- PRESS SW-BLOWER FAN, AVNCS VENT [17HQ]
- PRESS SW-BLOWER FAN, AVNCS VENT [19HQ]
- SENSOR-DUCT TEMP, AVNCS VENT [26HQ]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 24-00-00-810-803-A | Circuit Breaker Tripped and/or C/B TRIPPED Warning |
| AMM 21-26-00-710-001 | Operational Check of the Avionics Equipment Ventilation-System via MCDU |
| AMM 21-26-00-710-008 | Operational Test to Read the CFDS for CLASS 3 Faults of the AEVC |
| AMM 21-26-00-710-009 | Operational Test to Read the CFDS for LAST LEG REPORT of the AEVC |
| ASM 212602 | |
| ASM 212603 | |
| AMM 21-26-11-000-001 | Removal of the Blower and Extract Fan Pressure Switches |
| AMM 21-26-11-400-001 | Installation of the Blower and Extract Fan Pressure Switches |
| AMM 21-26-12-000-001 | Removal of the Avionics Ventilation Duct Temperature Sensor |
| AMM 21-26-12-400-001 | Installation of the Avionics Ventilation Duct Temperature Sensor |
| AMM 21-26-34-000-001 | Removal of the Avionics Equipment Ventilation Computer (AEVC) |
| AMM 21-26-34-400-001 | Installation of the Avionics Equipment Ventilation Computer (AEVC) |
Subtask 21-26-00-865-078-A
A. Table of the circuit breakers used in this procedure:
Subtask 21-26-00-710-121-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | AIR COND/AVNCS VENT/CTL | 6HQ | D06 |
| 49VU | AIR COND/AVNCS VENT/CTL | 5HQ | D05 |
| 122VU | AIR COND/AVNCS/VENT/MONG | 3HQ | Y17 |
B. Test
(1) Do the reset of the AEVC (10HQ).
(a) Open the circuit breaker AIR COND/AVNCS/VENT/MONG (3HQ).
(b) Wait for five seconds.
(c) Close the circuit breaker AIR COND/AVNCS/VENT/MONG (3HQ).
(2) Do the operational test of the avionics equipment ventilation from the Multipurpose Control and Display Unit (MCDU) AMM 21-26-00-710-001.
(3) Read the LAST LEG REPORT of the AEVC AMM 21-26-00-710-009.
(4) Read the CLASS 3 faults of the AEVC AMM 21-26-00-710-008.
4. Fault Isolation(1) Do the reset of the AEVC (10HQ).
(a) Open the circuit breaker AIR COND/AVNCS/VENT/MONG (3HQ).
(b) Wait for five seconds.
(c) Close the circuit breaker AIR COND/AVNCS/VENT/MONG (3HQ).
(2) Do the operational test of the avionics equipment ventilation from the Multipurpose Control and Display Unit (MCDU) AMM 21-26-00-710-001.
(3) Read the LAST LEG REPORT of the AEVC AMM 21-26-00-710-009.
(4) Read the CLASS 3 faults of the AEVC AMM 21-26-00-710-008.
Subtask 21-26-00-810-098-A
A. If the test gives the maintenance message CHECK AEVC SUPPLY:
Subtask 21-26-00-710-122-A - Do a check of the status of the AIR COND/AVNCS VENT/CTL circuit breaker (5HQ).
- Make sure that the VENTILATION/BLOWER pushbutton switch (13HQ) is pushed.
- Do a check for 28VDC at pin AA/7C and pin AA/1B of the AEVC (10HQ) ASM 212603 and ASM 212602
- Do a check for 28VDC at pin A/D3 of the VENTILATION/BLOWER pushbutton switch (13HQ) ASM 212603.
- Replace the
P/BSW-VENTILATION/BLOWER (13HQ) .
- Do a check of the wiring ASM 212603 between:
. Pin AA/7C of the AEVC (10HQ) and pin A/D1 of the VENTILLATION/BLOWER pushbutton switch (13HQ)
. Pin A/D3 of the VENTILLATION/BLOWER pushbutton switch (13HQ) and pin 2 of the AIR COND/AVNCS VENT/CTL circuit breaker (5HQ).
- Repair the related wiring .
- Replace the C/B-AIR COND/AVNCS VENT/CTL [5HQ] .
- Do a check of the wiring between pin AA/1B of the AEVC (10HQ) and pin 2 of the AIR COND/AVNCS VENT/CTL circuit breaker (5HQ) ASM 212602.
- Repair the related wiring .
- Replace the C/B-AIR COND/AVNCS VENT/CTL [5HQ] .
- Do a check of the status of the AIR COND/AVNCS VENT/CTL circuit breaker (6HQ).
- Make sure that the VENTILATION/EXTRACT pushbutton switch (14HQ) is pushed.
- Make sure that the CABIN PRESS/DITCHING pushbutton switch (13HL) is released.
- Do a check for 28VDC at pin AA/1C ASM 212603, at pin AA/2C and pin AA/3D ASM 212602 of the AEVC (10HQ).
- Do a check of the wiring between pin AA/1C of the AEVC (10HQ) and pin 2 of the AIR COND/AVNCS VENT/CTL circuit breaker (6HQ) ASM 212603.
* If there is no continuity:
* - Repair the related wiring.
* If there is continuity:
* - Replace the C/B-AIR COND/AVNCS VENT/CTL [6HQ] .
- Do a check for 28VDC at pin A/D3 of the VENTILATION/EXTRACT pushbutton switch (14HQ) ASM 212602.
* If there is 28VDC:
* - Replace theP/BSW-VENTILATION/EXTRACT (14HQ) .
* If there is no 28VDC:
* - Do a check of the wiring ASM 212602 between:
* . Pin AA/2C of the AEVC (10HQ) and pin A/D1 of the VENTILATION/EXTRACT pushbutton switch (14HQ)
* . Pin A/D3 of the VENTILATION/EXTRACT pushbutton switch (14HQ) and pin 2 of the AIR COND/AVNCS VENT/CTL circuit breaker (6HQ).
** If there is no continuity:
** - Repair the related wiring .
** If there is continuity:
** - Replace the C/B-AIR COND/AVNCS VENT/CTL [6HQ] .
- Release the VENTILATION/EXTRACT pushbutton switch (14HQ).
- Do a check for 28VDC at pin A/C3 of the VENTILATION/BLOWER pushbutton switch (13HQ) ASM 212602.
* If there is 28VDC:
* - Replace theP/BSW-VENTILATION/BLOWER (13HQ) .
* If there is no 28VDC:
* - Do a check of the wiring ASM 212602 between:
* . Pin AA/3D of the AEVC (10HQ) and pin A/C1 of the VENTILATION/BLOWER pushbutton switch (13HQ)
* . Pin A/C3 of the VENTILATION/BLOWER pushbutton switch (13HQ) and pin A/C2 of the VENTILATION/EXTRACT pushbutton switch (14HQ)
* . Pin A/C1 of the VENTILATION/EXTRACT pushbutton switch (14HQ) and pin AA/3D of the AEVC (10HQ).
** If there is no continuity:
** - Repair the related wiring .
** If there is continuity:
** - Do a check for 28VDC at pin A/C3 of the VENTILATION/EXTRACT pushbutton switch (14HQ) ASM 212602.
*** If there is 28VDC:
*** - Replace theP/BSW-VENTILATION/EXTRACT (14HQ) .
*** If there is no 28VDC:
*** - Do a check of the wiring between pin A/C3 of the VENTILATION/EXTRACT pushbutton switch (14HQ) and pin A/C2 of the CABIN PRESS/DITCHING pushbutton switch (13HL) ASM 212602.
**** If there is no continuity:
**** - Repair the related wiring .
**** If there is continuity:
**** - Do a check for 28VDC at pin A/C3 of the CABIN PRESS/DITCHING pushbutton switch (13HL) ASM 212602.
***** If there is 28VDC:
***** - Replace theP/BSW-CABIN PRESS/DITCHING (13HL) .
***** If there is no 28VDC:
***** - Do a check of the wiring between pin A/C3 of the CABIN PRESS/DITCHING pushbutton switch (13HL) and pin 2 of the AIR COND/AVNCS VENT/CTL circuit breaker (6HQ) ASM 212602.
****** If there is no continuity:
****** - Repair the related wiring.
****** If there is continuity:
****** - Replace the C/B-AIR COND/AVNCS VENT/CTL [6HQ] .
- Do a check for a ground signal at pin AA/1D of the AEVC (10HQ) ASM 212603.
* If there is a ground signal:
* - Replace the AEVC [10HQ] AMM 21-26-34-000-001 and AMM 21-26-34-400-001.
* If there is no ground signal:
* - Repair the wiring between the AEVC pin AA/1D and the ground terminal.
- Do the procedure (Ref. TSM TASK 24-00-00-810-803).
- Replace the C/B-AIR COND/AVNCS VENT/CTL [6HQ] .
- Replace the AEVC [10HQ] AMM 21-26-34-000-001 and AMM 21-26-34-400-001.
- Do the procedure (Ref. TSM TASK 24-00-00-810-803).
- Replace the C/B-AIR COND/AVNCS VENT/CTL [5HQ] .
- Replace the AEVC [10HQ] AMM 21-26-34-000-001 and AMM 21-26-34-400-001.
- Do a check of the wiring ASM 212603 between:
. Pin AB/8C of the AEVC (10HQ) and pin A/A of the blower fan pressure-switch (17HQ)
. Pin A/C of the blower fan pressure-switch (17HQ) and the ground.
- Repair the wiring .
- Replace the PRESS SW-BLOWER FAN, AVNCS VENT [17HQ] AMM 21-26-11-000-001 and AMM 21-26-11-400-001.
- Do a check of the wiring ASM 212603 between:
. Pin AB/8D of the AEVC (10HQ) and pin A/A of the blower fan pressure-switch (19HQ)
. Pin A/C of the blower fan pressure-switch (19HQ) and the ground.
- Repair the wiring .
- Replace the PRESS SW-BLOWER FAN, AVNCS VENT [19HQ] AMM 21-26-11-000-001 and AMM 21-26-11-400-001.
- Do a check of the wiring ASM 212603 between:
. Pin AB/5D of the AEVC (10HQ) and pin A/C of the duct temperature sensor (26HQ)
. Pin A/B of the duct temperature sensor (26HQ) and the ground.
- Repair the wiring .
- Replace the SENSOR-DUCT TEMP, AVNCS VENT [26HQ] AMM 21-26-12-000-001 and AMM 21-26-12-400-001.
B. Do the test given in Para. 3.