Avionics Ventilation System Bite Survey
TASK 21-26-00-810-836-A
Avionics Ventilation System Bite Survey
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 21-26-00-865-067-A
Subtask 21-26-00-810-093-A
[Rev.8 from Aug 2018]
2026.04.04 04:24:39 UTC
Avionics Ventilation System Bite Survey
1. Possible Causes
- AEVC [10HQ]
- SDAC-1 [1WV1]
- SDAC-2 [1WV2]
- wiring
- VALVE-SKIN AIR INLET, AVNCS VENT [15HQ]
- VALVE-SKIN AIR OUTLET, AVNCS VENT [22HQ]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 21-26-00-710-001 | Operational Check of the Avionics Equipment Ventilation-System via MCDU |
| AMM 21-26-00-710-008 | Operational Test to Read the CFDS for CLASS 3 Faults of the AEVC |
| AMM 21-26-00-710-009 | Operational Test to Read the CFDS for LAST LEG REPORT of the AEVC |
| ASM 212602 | |
| ASM 212603 | |
| AMM 21-26-34-000-001 | Removal of the Avionics Equipment Ventilation Computer (AEVC) |
| AMM 21-26-34-400-001 | Installation of the Avionics Equipment Ventilation Computer (AEVC) |
| AMM 21-26-52-000-001 | Removal of the Avionics-Ventilation Skin Air-Inlet-Valve |
| AMM 21-26-52-400-001 | Installation of the Avionics-Ventilation Skin Air-Inlet-Valve |
| AMM 21-26-53-000-002 | Removal of the Skin Air Outlet-Valve |
| AMM 21-26-53-400-001 | Installation of the Skin Air Outlet-Valve |
| AMM 31-55-34-000-001 | Removal of the SDAC |
| AMM 31-55-34-400-001 | Installation of the SDAC |
Subtask 21-26-00-865-067-A
A. Table of the circuit breakers used in this procedure:
Subtask 21-26-00-710-114-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 122VU | AIR COND/AVNCS/VENT/MONG | 3HQ | Y17 |
B. Test
(1) Do the reset of the AEVC (10HQ).
(a) Open the circuit breaker AIR COND/AVNCS/VENT/MONG (3HQ).
(b) Wait for five seconds.
(c) Close the circuit breaker AIR COND/AVNCS/VENT/MONG (3HQ).
(2) Do the operational test of the avionics equipment ventilation from the Multipurpose Control and Display Unit (MCDU) AMM 21-26-00-710-001.
(3) Read the LAST LEG REPORT of the AEVC AMM 21-26-00-710-009.
(4) Read the CLASS 3 faults of the AEVC AMM 21-26-00-710-008.
4. Fault Isolation(1) Do the reset of the AEVC (10HQ).
(a) Open the circuit breaker AIR COND/AVNCS/VENT/MONG (3HQ).
(b) Wait for five seconds.
(c) Close the circuit breaker AIR COND/AVNCS/VENT/MONG (3HQ).
(2) Do the operational test of the avionics equipment ventilation from the Multipurpose Control and Display Unit (MCDU) AMM 21-26-00-710-001.
(3) Read the LAST LEG REPORT of the AEVC AMM 21-26-00-710-009.
(4) Read the CLASS 3 faults of the AEVC AMM 21-26-00-710-008.
Subtask 21-26-00-810-093-A
A. If the fault symptom is identified by the ECAM warning VENT AVNCS SYS FAULT with no maintenance message AEVC and/or if the LAST LEG REPORT (LLR) shows no related CFDS message:
NOTE: On the ground, the ECAM warning VENT SKIN VALVE FAULT cannot come into view during the maintenance operations. It is replaced by the ECAM warning VENT AVNCS SYS FAULT.
- Replace the AEVC [10HQ] AMM 21-26-34-000-001 and AMM 21-26-34-400-001.
- Replace the SDAC-1 [1WV1] and the SDAC-2 [1WV2] AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
- Do a check and repair the wiring ASM 212602 ASM 212603 between:
. Pin AB/8A of the AEVC (10HQ) and pin AD/12C of the SDAC-1 (1WV1)
. Pin AB/8A of the AEVC (10HQ) and pin AD/12C of the SDAC-2 (1WV2)
. Pin A/M of the skin air-inlet valve (15HQ) and pin AD/11C of the SDAC-1 (1WV1)
. Pin A/M of the skin air-inlet valve (15HQ) and pin AD/11C of the SDAC-2 (1WV2)
. Pin A/J of the skin air-inlet valve (15HQ) and pin AD/10F of the SDAC-1 (1WV1)
. Pin A/J of the skin air-inlet valve (15HQ) and pin AD/10F of the SDAC-2 (1WV2)
. Pin A/J of the skin air-outlet valve (22HQ) and pin AD/9D of the SDAC-1 (1WV1)
. Pin A/J of the skin air-outlet valve (22HQ) and pin AD/9D of the SDAC-2 (1WV2)
. Pin A/M of the skin air-outlet valve (22HQ) and pin AD/9E of the SDAC-1 (1WV1)
. Pin A/M of the skin air-outlet valve (22HQ) and pin AD/9E of the SDAC-2 (1WV2)
. Pin A/R of the skin air-outlet valve (22HQ) and pin AD/10D of the SDAC-1 (1WV1)
. Pin A/R of the skin air-outlet valve (22HQ) and pin AD/10D of the SDAC-2 (1WV2).
- Replace the VALVE-SKIN AIR INLET, AVNCS VENT [15HQ] AMM 21-26-52-000-001 and AMM 21-26-52-400-001.
- Replace the VALVE-SKIN AIR OUTLET, AVNCS VENT [22HQ] AMM 21-26-53-000-002 and AMM 21-26-53-400-001.