Loss of the Duct Temperature Sensor
TASK 21-26-00-810-828-A
Loss of the Duct Temperature Sensor
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 21-26-00-865-069-A
Subtask 21-26-00-810-075-D
[Rev.8 from Aug 2018]
2026.04.04 04:24:38 UTC
Loss of the Duct Temperature Sensor
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 21-26-00-710-001 | Operational Check of the Avionics Equipment Ventilation-System via MCDU |
| AMM 21-26-00-710-002 | Operational Check of Override Function (BLOWER and EXTRACT) |
| AMM 21-26-00-710-008 | Operational Test to Read the CFDS for CLASS 3 Faults of the AEVC |
| AMM 21-26-00-710-009 | Operational Test to Read the CFDS for LAST LEG REPORT of the AEVC |
| ASM 212603 | |
| AMM 21-26-12-000-001 | Removal of the Avionics Ventilation Duct Temperature Sensor |
| AMM 21-26-12-400-001 | Installation of the Avionics Ventilation Duct Temperature Sensor |
| AMM 21-26-34-000-001 | Removal of the Avionics Equipment Ventilation Computer (AEVC) |
| AMM 21-26-34-400-001 | Installation of the Avionics Equipment Ventilation Computer (AEVC) |
| AMM 21-26-43-920-001 | Discard the Filter Cartridge (PALL) |
Subtask 21-26-00-865-069-A
A. Table of the circuit breakers used in this procedure:
Subtask 21-26-00-710-096-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 122VU | AIR COND/AVNCS/VENT/MONG | 3HQ | Y17 |
B. Test
(1) Do the reset of the AEVC (10HQ).
(a) Open the circuit breaker AIR COND/AVNCS/VENT/MONG (3HQ).
(b) Wait for five seconds.
(c) Close the circuit breaker AIR COND/AVNCS/VENT/MONG (3HQ).
(2) On the VENTILATION section of the overhead control and indicating panel 22VU, release the VENTILATION/BLOWER pushbutton switch (13HQ) (the OVRD legend comes on).
(3) Do the operational test of the avionics equipment ventilation from the Multipurpose Control and Display Unit (MCDU) AMM 21-26-00-710-001.
(4) Read the LAST LEG REPORT of the AEVC AMM 21-26-00-710-009.
(5) Read the CLASS 3 faults of the AEVC AMM 21-26-00-710-008.
4. Fault Isolation(1) Do the reset of the AEVC (10HQ).
(a) Open the circuit breaker AIR COND/AVNCS/VENT/MONG (3HQ).
(b) Wait for five seconds.
(c) Close the circuit breaker AIR COND/AVNCS/VENT/MONG (3HQ).
(2) On the VENTILATION section of the overhead control and indicating panel 22VU, release the VENTILATION/BLOWER pushbutton switch (13HQ) (the OVRD legend comes on).
(3) Do the operational test of the avionics equipment ventilation from the Multipurpose Control and Display Unit (MCDU) AMM 21-26-00-710-001.
(4) Read the LAST LEG REPORT of the AEVC AMM 21-26-00-710-009.
(5) Read the CLASS 3 faults of the AEVC AMM 21-26-00-710-008.
Subtask 21-26-00-810-075-D
A. If the fault symptom is identified by the maintenance message DUCT TEMP SENSOR 26HQ and the upper ECAM DU warning VENT BLOWER FAULT:
Subtask 21-26-00-710-097-A - Make sure that the avionics ventilation filter is not dirty.
- Replace the CARTRIDGE-AVNCS VENT FILTER [2082HM] AMM 21-26-43-920-001.
- Replace the SENSOR-DUCT TEMP, AVNCS VENT [26HQ] AMM 21-26-12-000-001 and AMM 21-26-12-400-001.
- Replace the AEVC [10HQ] AMM 21-26-34-000-001 and AMM 21-26-34-400-001.
- Do a check and repair the wiring ASM 212603 between:
. Pin AB/4D of the AEVC (10HQ) and pin A/E of the avionics-ventilation duct-temperature sensor (26HQ)
. Pin AB/5D of the AEVC (10HQ) and pin A/C of the avionics-ventilation duct-temperature sensor (26HQ)
. Pin A/F of the avionics-ventilation duct-temperature sensor (26HQ) and the ground
. Pin A/B of the avionics-ventilation duct-temperature sensor (26HQ) and the ground
. Pin 2 of the AIR COND/AVNCS/VENT/MONG circuit breaker (3HQ) and pin A/A of the avionics-ventilation duct-temperature sensor (26HQ).
B. Test
(1) On the VENTILATION section of the overhead control and indicating panel 22VU, push the VENTILATION/BLOWER pushbutton switch (13HQ) (the OVRD legend goes off).
(2) Do the operational test of the override function AMM 21-26-00-710-002 .
(1) On the VENTILATION section of the overhead control and indicating panel 22VU, push the VENTILATION/BLOWER pushbutton switch (13HQ) (the OVRD legend goes off).
(2) Do the operational test of the override function AMM 21-26-00-710-002 .