Loss of the Duct Temperature Sensor


TASK 21-26-00-810-828-A
Loss of the Duct Temperature Sensor


1. Possible Causes
  • CARTRIDGE-AVNCS VENT FILTER [2082HM]
  • SENSOR-DUCT TEMP, AVNCS VENT [26HQ]
  • AEVC [10HQ]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 21-26-00-710-001
Operational Check of the Avionics Equipment Ventilation-System via MCDU
AMM 21-26-00-710-002
Operational Check of Override Function (BLOWER and EXTRACT)
AMM 21-26-00-710-008
Operational Test to Read the CFDS for CLASS 3 Faults of the AEVC
AMM 21-26-00-710-009
Operational Test to Read the CFDS for LAST LEG REPORT of the AEVC
ASM 212603
AMM 21-26-12-000-001
Removal of the Avionics Ventilation Duct Temperature Sensor
AMM 21-26-12-400-001
Installation of the Avionics Ventilation Duct Temperature Sensor
AMM 21-26-34-000-001
Removal of the Avionics Equipment Ventilation Computer (AEVC)
AMM 21-26-34-400-001
Installation of the Avionics Equipment Ventilation Computer (AEVC)
AMM 21-26-43-920-001
Discard the Filter Cartridge (PALL)
3. Fault Confirmation
Subtask 21-26-00-865-069-A
A. Table of the circuit breakers used in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
122VUAIR COND/AVNCS/VENT/MONG3HQY17
Subtask 21-26-00-710-096-A
B. Test
   (1) Do the reset of the AEVC (10HQ).
     (a) Open the circuit breaker AIR COND/AVNCS/VENT/MONG (3HQ).
     (b) Wait for five seconds.
     (c) Close the circuit breaker AIR COND/AVNCS/VENT/MONG (3HQ).
   (2) On the VENTILATION section of the overhead control and indicating panel 22VU, release the VENTILATION/BLOWER pushbutton switch (13HQ) (the OVRD legend comes on).
   (3) Do the operational test of the avionics equipment ventilation from the Multipurpose Control and Display Unit (MCDU) AMM 21-26-00-710-001.
   (4) Read the LAST LEG REPORT of the AEVC AMM 21-26-00-710-009.
   (5) Read the CLASS 3 faults of the AEVC AMM 21-26-00-710-008.
4. Fault Isolation
Subtask 21-26-00-810-075-D
A. If the fault symptom is identified by the maintenance message DUCT TEMP SENSOR 26HQ and the upper ECAM DU warning VENT BLOWER FAULT:
  • Make sure that the avionics ventilation filter is not dirty.
   (1) If the avionics ventilation filter is dirty:
   (2) If the avionics ventilation filter is not dirty:
   (3) If the fault continues:
   (4) If the fault continues:
  • Do a check and repair the wiring ASM 212603 between:
    . Pin AB/4D of the AEVC (10HQ) and pin A/E of the avionics-ventilation duct-temperature sensor (26HQ)
    . Pin AB/5D of the AEVC (10HQ) and pin A/C of the avionics-ventilation duct-temperature sensor (26HQ)
    . Pin A/F of the avionics-ventilation duct-temperature sensor (26HQ) and the ground
    . Pin A/B of the avionics-ventilation duct-temperature sensor (26HQ) and the ground
    . Pin 2 of the AIR COND/AVNCS/VENT/MONG circuit breaker (3HQ) and pin A/A of the avionics-ventilation duct-temperature sensor (26HQ).
Subtask 21-26-00-710-097-A
B. Test
   (1) On the VENTILATION section of the overhead control and indicating panel 22VU, push the VENTILATION/BLOWER pushbutton switch (13HQ) (the OVRD legend goes off).
   (2) Do the operational test of the override function AMM 21-26-00-710-002 .