No Transmission by the ARINC 429 Bus


TASK 21-26-00-810-826-A
No Transmission by the ARINC 429 Bus


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 212602
ASM 212603
AMM 21-26-34-000-001
Removal of the Avionics Equipment Ventilation Computer (AEVC)
AMM 21-26-34-400-001
Installation of the Avionics Equipment Ventilation Computer (AEVC)
AMM 31-32-00-869-002
Procedure for the Class 3 Fault Reading
ASM 313206
AMM 31-32-34-000-001
Removal of the CFDIU
AMM 31-32-34-400-001
Installation of the CFDIU
3. Fault Confirmation
Subtask 21-26-00-740-050-A
A. Test
   (1) On the CFDS MENU page, get access to the AVIONICS STATUS page AMM 31-32-00-869-002.
4. Fault Isolation
Subtask 21-26-00-810-065-A
A. If the test gives the maintenance message NO AEVC DATA:
  • Do a check of the wiring ASM 212602 and ASM 313206 between:
    . Pin AB/12A of the AEVC (10HQ) and pin AB/10A of the CFDIU (1TW)
    . Pin AB/13A of the AEVC (10HQ) and pin AA/3D of the CFDIU (1TW)
    . Pin AB/14A of the AEVC (10HQ) and pin AA/3E of the CFDIU (1TW).
   (1) If the wiring is not correct:
  • Repair the related wiring.
   (2) If the wiring is correct:
     (a) If the fault continues:
  • Do a check of the wiring ASM 212603 between pin 2 of the AIR COND/AVNCS/VENT/MONG circuit breaker (3HQ) and pin AA/1A of the AEVC (10HQ).
       1 If the wiring is not correct:
  • Repair the related wiring.
       2 If the wiring is correct:
Subtask 21-26-00-740-051-A
B. Do the operational test given in Para. 3.