W DOC AIRBUS | TSM A320F

Warning of the Duct Temperature Sensor Inoperative


TASK 21-26-00-810-818-A
Warning of the Duct Temperature Sensor Inoperative


1. Possible Causes
  • SENSOR-DUCT TEMP, AVNCS VENT [26HQ]
  • wiring between the AEVC (10HQ) and the duct temperature sensor (26HQ)
  • AEVC [10HQ]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 21-26-00-710-001
Operational Check of the Avionics Equipment Ventilation-System via MCDU
ASM 212603
AMM 21-26-12-000-001
Removal of the Avionics Ventilation Duct Temperature Sensor
AMM 21-26-12-400-001
Installation of the Avionics Ventilation Duct Temperature Sensor
AMM 21-26-34-000-001
Removal of the Avionics Equipment Ventilation Computer (AEVC)
AMM 21-26-34-400-001
Installation of the Avionics Equipment Ventilation Computer (AEVC)
3. Fault Confirmation
Subtask 21-26-00-710-062-A
A. Test
   (1) Do the operational test of the avionics equipment ventilation from the Multipurpose Control and Display Unit (MCDU) AMM 21-26-00-710-001.
4. Fault Isolation
Subtask 21-26-00-810-056-A
A. If the test gives the maintenance message DUCT TEMP SENSOR 26HQ:
   (1) If the fault continues:
  • Do a check and repair the wiring between the AEVC (10HQ) and the duct temperature sensor (26HQ), pins AB/5D and pins A/C ASM 212603.
     (a) If the fault continues:
Subtask 21-26-00-710-063-A
B. Do the operational test given in Para. 3.