Unwanted Warning of the Duct Temperature Sensor
TASK 21-26-00-810-817-A
Unwanted Warning of the Duct Temperature Sensor
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 21-26-00-865-080-A
Subtask 21-26-00-810-055-D
[Rev.8 from Aug 2018]
2026.04.04 04:24:37 UTC
Unwanted Warning of the Duct Temperature Sensor
1. Possible Causes
- CARTRIDGE-AVNCS VENT FILTER [2082HM]
- CHECK VALVE-AIR INLET, AVNCS VENT [2150HM]
- PRESS SW-BLOWER FAN, AVNCS VENT [17HQ]
- PRESS SW-BLOWER FAN, AVNCS VENT [19HQ]
- SENSOR-DUCT TEMP, AVNCS VENT [26HQ]
- FAN-BLOWER, AVNCS VENT [20HQ]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 21-26-00-710-001 | Operational Check of the Avionics Equipment Ventilation-System via MCDU |
| AMM 21-26-00-710-008 | Operational Test to Read the CFDS for CLASS 3 Faults of the AEVC |
| AMM 21-26-00-710-009 | Operational Test to Read the CFDS for LAST LEG REPORT of the AEVC |
| ASM 212603 | |
| AMM 21-26-11-000-001 | Removal of the Blower and Extract Fan Pressure Switches |
| AMM 21-26-11-400-001 | Installation of the Blower and Extract Fan Pressure Switches |
| AMM 21-26-12-000-001 | Removal of the Avionics Ventilation Duct Temperature Sensor |
| AMM 21-26-12-400-001 | Installation of the Avionics Ventilation Duct Temperature Sensor |
| AMM 21-26-43-920-001 | Discard the Filter Cartridge (PALL) |
| AMM 21-26-51-000-001 | Removal of the Extract and Blower Fans |
| AMM 21-26-51-400-001 | Installation of the Extract and Blower Fans |
| AMM 21-26-56-000-001 | Removal of the Air Inlet Check Valve |
| AMM 21-26-56-280-002 | Operational Check of Air Inlet Check Valve |
| AMM 21-26-56-400-001 | Installation of the Air Inlet Check Valve |
Subtask 21-26-00-865-080-A
A. Table of the circuit breakers used in this procedure:
Subtask 21-26-00-710-060-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 122VU | AIR COND/AVNCS/VENT/MONG | 3HQ | Y17 |
B. Test
(1) Do the reset of the AEVC (10HQ).
(a) Open the circuit breaker AIR COND/AVNCS/VENT/MONG (3HQ).
(b) Wait for five seconds.
(c) Close the circuit breaker AIR COND/AVNCS/VENT/MONG (3HQ).
(2) Do the operational test of the avionics equipment ventilation from the Multipurpose Control and Display Unit (MCDU) AMM 21-26-00-710-001.
(3) Read the LAST LEG REPORT of the AEVC AMM 21-26-00-710-009.
(4) Read the CLASS 3 faults of the AEVC AMM 21-26-00-710-008.
4. Fault Isolation(1) Do the reset of the AEVC (10HQ).
(a) Open the circuit breaker AIR COND/AVNCS/VENT/MONG (3HQ).
(b) Wait for five seconds.
(c) Close the circuit breaker AIR COND/AVNCS/VENT/MONG (3HQ).
(2) Do the operational test of the avionics equipment ventilation from the Multipurpose Control and Display Unit (MCDU) AMM 21-26-00-710-001.
(3) Read the LAST LEG REPORT of the AEVC AMM 21-26-00-710-009.
(4) Read the CLASS 3 faults of the AEVC AMM 21-26-00-710-008.
Subtask 21-26-00-810-055-D
A. If the fault symptom is identified by the upper ECAM DU warning VENT BLOWER FAULT and if the result of the operational test gives the "TEST OK" message:
Subtask 21-26-00-710-061-A - Make sure that the avionics ventilation filter not dirty.
- Replace the CARTRIDGE-AVNCS VENT FILTER [2082HM] AMM 21-26-43-920-001.
- Do the operational check of the air inlet check-valve (2150HM) AMM 21-26-56-280-002.
- Replace the CHECK VALVE-AIR INLET, AVNCS VENT [2150HM] AMM 21-26-56-000-001 and AMM 21-26-56-400-001.
- Replace the PRESS SW-BLOWER FAN, AVNCS VENT [17HQ] AMM 21-26-11-000-001 and AMM 21-26-11-400-001.
- Replace the PRESS SW-BLOWER FAN, AVNCS VENT [19HQ] AMM 21-26-11-000-001 and AMM 21-26-11-400-001.
- Replace the SENSOR-DUCT TEMP, AVNCS VENT [26HQ] AMM 21-26-12-000-001 and AMM 21-26-12-400-001.
- Replace the FAN-BLOWER, AVNCS VENT [20HQ] AMM 21-26-51-000-001 and AMM 21-26-51-400-001.
- Continue with the subsequent step.
- The AEVC (10HQ) and the blower fan pressure-switch (17HQ), pin AB/8C and pin A/A
- The blower fan pressure-switch (17HQ), pin A/C and the ground
- The AEVC (10HQ) and blower fan pressure-switch (19HQ), pin AB/8D and pin A/A
- The blower fan pressure-switch (19HQ), pin A/C and the ground
- The SDAC-1 (1WV1), SDAC-2 (1WV2) and the blower fan pressure-switch (17HQ), pin AD/9F and pin A/A (through the diode module 1800VD)
- The SDAC-1 (1WV1), SDAC-2 (1WV2) and the blower fan pressure-switch (19HQ), pin AD/9F and pin A/A (through the diode module 1800VD).
- Repair the related wiring .
- Do a check and repair the wiring ASM 212603 between:
. Pin AB/4D of the AEVC (10HQ) and pin A/E of the avionics-ventilation duct-temperature sensor (26HQ)
. Pin AB/5D of the AEVC (10HQ) and pin A/C of the avionics-ventilation duct-temperature sensor (26HQ)
. Pin A/F of the avionics-ventilation duct-temperature sensor (26HQ) and the ground
. Pin A/B of the avionics-ventilation duct-temperature sensor (26HQ) and the ground
. Pin 2 of the AIR COND/AVNCS/VENT/MONG circuit breaker (3HQ) and pin A/A of the avionics-ventilation duct-temperature sensor (26HQ)
. The SDAC-1 (1WV1), SDAC-2 (1WV2) and the avionics-ventilation duct-temperature sensor (26HQ), pin AD/9F and pin A/C (through the diode module 1800VD).
B. Do the operational test given in Para. 3.