Warning of the Blower-Fan Pressure Switch Inoperative


TASK 21-26-00-810-815-A
Warning of the Blower-Fan Pressure Switch Inoperative


1. Possible Causes
  • PRESS SW-BLOWER FAN, AVNCS VENT [17HQ]
  • AEVC [10HQ]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 21-26-00-710-001
Operational Check of the Avionics Equipment Ventilation-System via MCDU
AMM 21-26-00-710-008
Operational Test to Read the CFDS for CLASS 3 Faults of the AEVC
AMM 21-26-00-710-009
Operational Test to Read the CFDS for LAST LEG REPORT of the AEVC
ASM 212603
AMM 21-26-11-000-001
Removal of the Blower and Extract Fan Pressure Switches
AMM 21-26-11-400-001
Installation of the Blower and Extract Fan Pressure Switches
AMM 21-26-34-000-001
Removal of the Avionics Equipment Ventilation Computer (AEVC)
AMM 21-26-34-400-001
Installation of the Avionics Equipment Ventilation Computer (AEVC)
3. Fault Confirmation
Subtask 21-26-00-865-070-A
A. Table of the circuit breakers used in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
122VUAIR COND/AVNCS/VENT/MONG3HQY17
Subtask 21-26-00-710-056-A
B. Test
   (1) Do the reset of the AEVC (10HQ).
     (a) Open the circuit breaker AIR COND/AVNCS/VENT/MONG (3HQ).
     (b) Wait for five seconds.
     (c) Close the circuit breaker AIR COND/AVNCS/VENT/MONG (3HQ).
   (2) Do the operational test of the avionics equipment ventilation from the Multipurpose Control and Display Unit (MCDU) AMM 21-26-00-710-001.
   (3) Read the LAST LEG REPORT of the AEVC AMM 21-26-00-710-009.
   (4) Read the CLASS 3 faults of the AEVC AMM 21-26-00-710-008.
4. Fault Isolation
Subtask 21-26-00-810-053-A
A. If the test gives the maintenance message PRESSURE SW 17HQ:
   (1) If the fault continues:
   (2) If the fault continues:
  • Do a check and repair the wiring ASM 212603 between:
    . Pin AB/8C of the AEVC (10HQ) and pin A/A of the blower fan pressure-switch (17HQ)
    . Pin A/C of the blower fan pressure-switch (17HQ) and the ground.
Subtask 21-26-00-710-057-A
B. Do the operational test given in Para. 3.