Failure of the Smoke Detector
TASK 21-26-00-810-811-A
Failure of the Smoke Detector
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 21-26-00-710-073-A
Subtask 21-26-00-865-052-A
[Rev.8 from Aug 2018]
2026.04.04 04:24:37 UTC
Failure of the Smoke Detector
1. Possible Causes
- DET-SMOKE, AVNCS COMPT [1WA]
RELAY-SMOKE WARNING, AVNCS COMPT (2WA) - AEVC [10HQ]
- C/B-AIR COND/AVNCS VENT/CTL [5HQ]
wiring between pin A/A of the smoke detector (1WA) and the circuit breaker (5HQ)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 21-26-00-710-001 | Operational Check of the Avionics Equipment Ventilation-System via MCDU |
| ASM 212603 | |
| AWM 212606 | |
| AWM 212608 | |
| AMM 21-26-34-000-001 | Removal of the Avionics Equipment Ventilation Computer (AEVC) |
| AMM 21-26-34-400-001 | Installation of the Avionics Equipment Ventilation Computer (AEVC) |
| AWM 261501 | |
| AMM 26-15-15-000-001 | Removal of the Smoke Detector - Avionics Compartment |
| AMM 26-15-15-400-001 | Installation of the Smoke Detector - Avionics Compartment |
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
Subtask 21-26-00-710-073-A
A. Test
(1) Do the operational test of the avionics equipment ventilation from the Multipurpose Control and Display Unit (MCDU) AMM 21-26-00-710-001.
4. Fault Isolation(1) Do the operational test of the avionics equipment ventilation from the Multipurpose Control and Display Unit (MCDU) AMM 21-26-00-710-001.
Subtask 21-26-00-865-052-A
A. Table of the circuit breakers used in this procedure:
Subtask 21-26-00-810-062-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | AIR COND/AVNCS VENT/CTL | 5HQ | D05 |
B. If the test gives the maintenance message SMOKE DETECTOR 1WA:
Subtask 21-26-00-710-074-A - Do a check of the status of the circuit breaker (5HQ).
- Do a check for a ground signal at pin AB/7D of the AEVC (10HQ) ASM 212603.
- Do a check for 28VDC at pin A/X1 of the smoke warning relay (2WA) AWM 261501.
- Replace the DET-SMOKE, AVNCS COMPT [1WA] AMM 26-15-15-000-001 and AMM 26-15-15-400-001.
- Replace the
RELAY-SMOKE WARNING, AVNCS COMPT (2WA)
- Do a check and repair the wiring between the smoke warning relay (2WA) and the AEVC (10HQ), pin A/A1 and pin AB/7D ASM 212603 AWM 261501 AWM 212606.
- Replace the AEVC [10HQ] AMM 21-26-34-000-001 and AMM 21-26-34-400-001.
- Do a check for a ground signal at pin A/A2 of the smoke warning relay (2WA).
- Do a check for 28VDC at pin A/X1 of the smoke warning relay (2WA).
- Replace the
RELAY-SMOKE WARNING, AVNCS COMPT (2WA) .
* If the fault continues:
* - Do a check and repair the wiring between the smoke warning relay (2WA) and the smoke detector (1WA), pin A/X1 and pin A/D ASM 212603 AWM 261501.
- Do a check for 28VDC at pin A/A of the smoke detector (1WA).
* If there is 28VDC:
* - Replace the DET-SMOKE, AVNCS COMPT [1WA] AMM 26-15-15-000-001 and AMM 26-15-15-400-001.
* If there is no 28VDC:
* - Replace the C/B-AIR COND/AVNCS VENT/CTL [5HQ] .
** If the fault continues:
** - Do a check and repair thewiring between pin A/A of the smoke detector (1WA) and the circuit breaker (5HQ) ASM 212603 AWM 212608 AWM 261501.
C. Do the operational test given in Para. 3.
Subtask 21-26-00-865-055-A D. Table of the circuit breakers used in this procedure:
Subtask 21-26-00-710-112-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | FWS/FWC1/SPLY | 3WW | F01 |
| 121VU | EIS/FWC2/SPLY | 2WW | Q07 |
E. Test
(1) Reset of the FWC1 and FWC2
1 2WW
2 3WW.
(b) Close this(these) circuit breaker(s):
1 2WW
2 3WW.
(2) Do the ground scanning of the central warning system AMM 31-50-00-710-001.
(1) Reset of the FWC1 and FWC2
NOTE: The reset of the FWC will clear the latched condition of the AVIONICS SMOKE ECAM warning. Then, no unwanted LAND ASAP message will show.
NOTE: It is necessary to open the circuit breakers for a minimum of five seconds before they are closed.
(a) Open this(these) circuit breaker(s):1 2WW
2 3WW.
(b) Close this(these) circuit breaker(s):
1 2WW
2 3WW.
(2) Do the ground scanning of the central warning system AMM 31-50-00-710-001.