Failure of the Smoke Detector


TASK 21-26-00-810-811-A
Failure of the Smoke Detector


1. Possible Causes
  • DET-SMOKE, AVNCS COMPT [1WA]
  • RELAY-SMOKE WARNING, AVNCS COMPT (2WA)
  • AEVC [10HQ]
  • C/B-AIR COND/AVNCS VENT/CTL [5HQ]
  • wiring between pin A/A of the smoke detector (1WA) and the circuit breaker (5HQ)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 21-26-00-710-001
Operational Check of the Avionics Equipment Ventilation-System via MCDU
ASM 212603
AWM 212606
AWM 212608
AMM 21-26-34-000-001
Removal of the Avionics Equipment Ventilation Computer (AEVC)
AMM 21-26-34-400-001
Installation of the Avionics Equipment Ventilation Computer (AEVC)
AWM 261501
AMM 26-15-15-000-001
Removal of the Smoke Detector - Avionics Compartment
AMM 26-15-15-400-001
Installation of the Smoke Detector - Avionics Compartment
AMM 31-50-00-710-001
Ground Scanning of the Central Warning System
3. Fault Confirmation
Subtask 21-26-00-710-073-A
A. Test
   (1) Do the operational test of the avionics equipment ventilation from the Multipurpose Control and Display Unit (MCDU) AMM 21-26-00-710-001.
4. Fault Isolation
Subtask 21-26-00-865-052-A
A. Table of the circuit breakers used in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUAIR COND/AVNCS VENT/CTL5HQD05
Subtask 21-26-00-810-062-A
B. If the test gives the maintenance message SMOKE DETECTOR 1WA:
  • Do a check of the status of the circuit breaker (5HQ).
   (1) If the circuit breaker (5HQ) is closed:
  • Do a check for a ground signal at pin AB/7D of the AEVC (10HQ) ASM 212603.
     (a) If there is a ground signal:
  • Do a check for 28VDC at pin A/X1 of the smoke warning relay (2WA) AWM 261501.
       1 If there is 28VDC:
       2 If there is no 28VDC:
  • Replace the RELAY-SMOKE WARNING, AVNCS COMPT (2WA)
         a If the fault continues:
         b If the fault continues:
     (b) If there is no ground signal:
  • Do a check for a ground signal at pin A/A2 of the smoke warning relay (2WA).
       1 If there is a ground signal:
  • Do a check for 28VDC at pin A/X1 of the smoke warning relay (2WA).
         a If there is 28VDC:
  • Replace the RELAY-SMOKE WARNING, AVNCS COMPT (2WA).
    * If the fault continues:
    * - Do a check and repair the wiring between the smoke warning relay (2WA) and the smoke detector (1WA), pin A/X1 and pin A/D ASM 212603 AWM 261501.
         b If there is no 28VDC:
  • Do a check for 28VDC at pin A/A of the smoke detector (1WA).

    * If there is 28VDC:
    * - Replace the DET-SMOKE, AVNCS COMPT [1WA] AMM 26-15-15-000-001 and AMM 26-15-15-400-001.

    * If there is no 28VDC:
    * - Replace the C/B-AIR COND/AVNCS VENT/CTL [5HQ] .

    ** If the fault continues:
    ** - Do a check and repair the wiring between pin A/A of the smoke detector (1WA) and the circuit breaker (5HQ) ASM 212603 AWM 212608 AWM 261501.
Subtask 21-26-00-710-074-A
C. Do the operational test given in Para. 3.
Subtask 21-26-00-865-055-A
D. Table of the circuit breakers used in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUFWS/FWC1/SPLY3WWF01
121VUEIS/FWC2/SPLY2WWQ07
Subtask 21-26-00-710-112-A
E. Test
   (1) Reset of the FWC1 and FWC2
NOTE: The reset of the FWC will clear the latched condition of the AVIONICS SMOKE ECAM warning. Then, no unwanted LAND ASAP message will show.
NOTE: It is necessary to open the circuit breakers for a minimum of five seconds before they are closed.
     (a) Open this(these) circuit breaker(s):
       1 2WW
       2 3WW.
     (b) Close this(these) circuit breaker(s):
       1 2WW
       2 3WW.
   (2) Do the ground scanning of the central warning system AMM 31-50-00-710-001.