Failure of the Extract Fan
TASK 21-26-00-810-810-A
Failure of the Extract Fan
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 21-26-00-865-054-A
Subtask 21-26-00-810-073-A
[Rev.8 from Aug 2018]
2026.04.04 04:24:37 UTC
Failure of the Extract Fan
1. Possible Causes
CNTOR-EXTRACT FAN CTL, AVNCS VENT (7HQ) - FAN-EXTRACT, AVNCS VENT [18HQ]
- C/B-AVNCS VENT/EXTC/FAN [2HQ]
- AEVC [10HQ]
- wiring
- C/B-AIR COND/AVNCS VENT/CTL [6HQ]
- PRESS SW-EXTRACT FAN, AVNCS VENT [30HQ]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 24-00-00-810-803-A | Circuit Breaker Tripped and/or C/B TRIPPED Warning |
| AMM 21-26-00-710-001 | Operational Check of the Avionics Equipment Ventilation-System via MCDU |
| AMM 21-26-00-710-008 | Operational Test to Read the CFDS for CLASS 3 Faults of the AEVC |
| AMM 21-26-00-710-009 | Operational Test to Read the CFDS for LAST LEG REPORT of the AEVC |
| ASM 212602 | |
| AMM 21-26-11-000-001 | Removal of the Blower and Extract Fan Pressure Switches |
| AMM 21-26-11-400-001 | Installation of the Blower and Extract Fan Pressure Switches |
| AMM 21-26-34-000-001 | Removal of the Avionics Equipment Ventilation Computer (AEVC) |
| AMM 21-26-34-400-001 | Installation of the Avionics Equipment Ventilation Computer (AEVC) |
| AMM 21-26-51-000-001 | Removal of the Extract and Blower Fans |
| AMM 21-26-51-400-001 | Installation of the Extract and Blower Fans |
Subtask 21-26-00-865-054-A
A. Table of the circuit breakers used in this procedure:
Subtask 21-26-00-710-092-B | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | AIR COND/AVNCS VENT/CTL | 6HQ | D06 |
| 122VU | AIR COND/AVNCS/VENT/MONG | 3HQ | Y17 |
| ** ON A/C NOT FOR ALL | |||
| 123VU | AVNCS VENT/EXTC/FAN | 2HQ | AE02 |
| ** ON A/C NOT FOR ALL | |||
| 123VU | AVNCS VENT/EXTC/FAN | 2HQ | AC04 |
B. Test
(1) Do the reset of the AEVC (10HQ).
(a) Open the circuit breaker AIR COND/AVNCS/VENT/MONG (3HQ).
(b) Wait for five seconds.
(c) Close the circuit breaker AIR COND/AVNCS/VENT/MONG (3HQ).
(2) Do the operational test of the avionics equipment ventilation from the Multipurpose Control and Display Unit (MCDU) AMM 21-26-00-710-001.
(3) Read the LAST LEG REPORT AMM 21-26-00-710-009.
(4) Read the CLASS 3 faults of the AEVC AMM 21-26-00-710-008.
4. Fault Isolation(1) Do the reset of the AEVC (10HQ).
(a) Open the circuit breaker AIR COND/AVNCS/VENT/MONG (3HQ).
(b) Wait for five seconds.
(c) Close the circuit breaker AIR COND/AVNCS/VENT/MONG (3HQ).
(2) Do the operational test of the avionics equipment ventilation from the Multipurpose Control and Display Unit (MCDU) AMM 21-26-00-710-001.
(3) Read the LAST LEG REPORT AMM 21-26-00-710-009.
(4) Read the CLASS 3 faults of the AEVC AMM 21-26-00-710-008.
Subtask 21-26-00-810-073-A
A. If the test gives the maintenance message EXTRACT FAN 18HQ:
(1) If the AVNCS VENT/EXTC/FAN circuit breaker (2HQ) is open:
** - Replace the FAN-EXTRACT, AVNCS VENT [18HQ] AMM 21-26-51-000-001 and AMM 21-26-51-400-001.
** If the fault continues:
** - Do a check for 28VDC at pin AA/9A of the AEVC (10HQ) ASM 212602.
*** If there is 28VDC:
*** - Replace the AEVC [10HQ] AMM 21-26-34-000-001 and AMM 21-26-34-400-001.
*** If there is no 28VDC:
*** - Do a check of the wiring ASM 212602 between:
*** . The AEVC (10HQ), pin AA/9A and the extract-fan control contactor (7HQ), pin Z
*** . The extract-fan control contactor (7HQ), pin X and the extract fan (18HQ), pin A/D.
**** If the wiring is not correct:
**** - Repair the related wiring.
**** If the wiring is correct:
**** - Replace theCNTOR-EXTRACT FAN CTL, AVNCS VENT (7HQ) .
**** If the fault continues:
**** - Replace the FAN-EXTRACT, AVNCS VENT [18HQ] AMM 21-26-51-000-001 and AMM 21-26-51-400-001.
b If the AIR COND/AVNCS VENT/CTL circuit breaker (6HQ) is open:
Subtask 21-26-00-710-093-A (1) If the AVNCS VENT/EXTC/FAN circuit breaker (2HQ) is open:
- Do the procedure (Ref. TSM TASK 24-00-00-810-803).
- Replace the
CNTOR-EXTRACT FAN CTL, AVNCS VENT (7HQ) .
- Replace the FAN-EXTRACT, AVNCS VENT [18HQ] AMM 21-26-51-000-001 and AMM 21-26-51-400-001.
- Replace the C/B-AVNCS VENT/EXTC/FAN [2HQ] .
- Replace the AEVC [10HQ] AMM 21-26-34-000-001 and AMM 21-26-34-400-001.
- Do a check of the status of the AVNCS VENT/EXTC/FAN circuit breaker (2HQ).
- Do a check for 115VAC at pins A/J, A/K, A/L of the extract fan (18HQ).
- Do a check for 115VAC at pins T1, T2, T3 of the extract-fan control contactor (7HQ).
- Do a check of the wiring ASM 212602 between the extract-fan control contactor (7HQ) pins L1, L2, L3 and the AVNCS VENT/EXTC/FAN circuit breaker (2HQ) pins A2, B2, C2.
- Repair the related wiring.
- Replace the C/B-AVNCS VENT/EXTC/FAN [2HQ] .
- Do a check of the status of the AIR COND/AVNCS VENT/CTL circuit breaker (6HQ).
- Do a check for 28VDC at pin A/E of the extract fan (18HQ).
* If there is no 28VDC:
* - Do a check of the wiring ASM 212602 between:
* . The extract fan (18HQ) pin A/E and the AIR COND/AVNCS VENT/CTL circuit breaker (6HQ)
* . The extract fan (18HQ) pin A/F and the ground.
** If the wiring is not correct:
** - Repair the related wiring.
** If the wiring is correct:
** - Replace the C/B-AIR COND/AVNCS VENT/CTL [6HQ] .
* If there is 28VDC:
* - Make sure that the warning light of the extract fan (18HQ) is off.
** If the warning light is on, push the RESET pushbutton switch on the extract fan (18HQ).
NOTE: The fan starts immediately.
The warning light goes off.
** If the fault continues: The warning light goes off.
** - Replace the FAN-EXTRACT, AVNCS VENT [18HQ] AMM 21-26-51-000-001 and AMM 21-26-51-400-001.
** If the fault continues:
** - Do a check for 28VDC at pin AA/9A of the AEVC (10HQ) ASM 212602.
*** If there is 28VDC:
*** - Replace the AEVC [10HQ] AMM 21-26-34-000-001 and AMM 21-26-34-400-001.
*** If there is no 28VDC:
*** - Do a check of the wiring ASM 212602 between:
*** . The AEVC (10HQ), pin AA/9A and the extract-fan control contactor (7HQ), pin Z
*** . The extract-fan control contactor (7HQ), pin X and the extract fan (18HQ), pin A/D.
**** If the wiring is not correct:
**** - Repair the related wiring.
**** If the wiring is correct:
**** - Replace the
**** If the fault continues:
**** - Replace the FAN-EXTRACT, AVNCS VENT [18HQ] AMM 21-26-51-000-001 and AMM 21-26-51-400-001.
b If the AIR COND/AVNCS VENT/CTL circuit breaker (6HQ) is open:
- Do the procedure (Ref. TSM TASK 24-00-00-810-803).
* If the fault continues:
* - Replace the C/B-AIR COND/AVNCS VENT/CTL [6HQ] .
- Replace the FAN-EXTRACT, AVNCS VENT [18HQ] AMM 21-26-51-000-001 and AMM 21-26-51-400-001.
- Replace the PRESS SW-EXTRACT FAN, AVNCS VENT [30HQ] AMM 21-26-11-000-001 and AMM 21-26-11-400-001.
B. Do the operational test given in Para. 3.