Failure of the Blower Fan
TASK 21-26-00-810-809-A
Failure of the Blower Fan
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 21-26-00-865-053-A
Subtask 21-26-00-810-072-D
[Rev.8 from Aug 2018]
2026.04.04 04:24:37 UTC
Failure of the Blower Fan
1. Possible Causes
CNTOR-BLOWER FAN CTL, AVNCS VENT (8HQ) - FAN-BLOWER, AVNCS VENT [20HQ]
- C/B-AVNCS VENT/BLOWER/FAN [1HQ]
- CARTRIDGE-AVNCS VENT FILTER [2082HM]
- AEVC [10HQ]
- wiring
- C/B-AIR COND/AVNCS/VENT/MONG [3HQ]
- PRESS SW-BLOWER FAN, AVNCS VENT [17HQ]
- PRESS SW-BLOWER FAN, AVNCS VENT [19HQ]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 24-00-00-810-803-A | Circuit Breaker Tripped and/or C/B TRIPPED Warning |
| AMM 21-26-00-710-001 | Operational Check of the Avionics Equipment Ventilation-System via MCDU |
| AMM 21-26-00-710-008 | Operational Test to Read the CFDS for CLASS 3 Faults of the AEVC |
| AMM 21-26-00-710-009 | Operational Test to Read the CFDS for LAST LEG REPORT of the AEVC |
| ASM 212603 | |
| AMM 21-26-11-000-001 | Removal of the Blower and Extract Fan Pressure Switches |
| AMM 21-26-11-400-001 | Installation of the Blower and Extract Fan Pressure Switches |
| AMM 21-26-34-000-001 | Removal of the Avionics Equipment Ventilation Computer (AEVC) |
| AMM 21-26-34-400-001 | Installation of the Avionics Equipment Ventilation Computer (AEVC) |
| AMM 21-26-43-920-001 | Discard the Filter Cartridge (PALL) |
| AMM 21-26-51-000-001 | Removal of the Extract and Blower Fans |
| AMM 21-26-51-400-001 | Installation of the Extract and Blower Fans |
Subtask 21-26-00-865-053-A
A. Table of the circuit breakers used in this procedure:
Subtask 21-26-00-710-090-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 122VU | AIR COND/AVNCS/VENT/MONG | 3HQ | Y17 |
| 123VU | AVNCS VENT/BLOWER/FAN | 1HQ | AD10 |
B. Test
(1) Do the reset of the AEVC (10HQ).
(a) Open the circuit breaker AIR COND/AVNCS/VENT/MONG (3HQ).
(b) Wait for five seconds.
(c) Close the circuit breaker AIR COND/AVNCS/VENT/MONG (3HQ).
(2) Do the operational test of the avionics equipment ventilation from the Multipurpose Control and Display Unit (MCDU) AMM 21-26-00-710-001.
(3) Read the LAST LEG REPORT of the AEVC AMM 21-26-00-710-009.
(4) Read the CLASS 3 faults of the AEVC AMM 21-26-00-710-008.
4. Fault Isolation(1) Do the reset of the AEVC (10HQ).
(a) Open the circuit breaker AIR COND/AVNCS/VENT/MONG (3HQ).
(b) Wait for five seconds.
(c) Close the circuit breaker AIR COND/AVNCS/VENT/MONG (3HQ).
(2) Do the operational test of the avionics equipment ventilation from the Multipurpose Control and Display Unit (MCDU) AMM 21-26-00-710-001.
(3) Read the LAST LEG REPORT of the AEVC AMM 21-26-00-710-009.
(4) Read the CLASS 3 faults of the AEVC AMM 21-26-00-710-008.
Subtask 21-26-00-810-072-D
A. If the test gives the maintenance message BLOWER FAN 20HQ:
** - Replace FAN-BLOWER, AVNCS VENT [20HQ] AMM 21-26-51-000-001 and AMM 21-26-51-400-001.
** If the fault continues:
** - Do a check for 28VDC at pin AA/8A of the AEVC (10HQ) ASM 212603.
*** If there is 28VDC:
*** - Replace AEVC [10HQ] AMM 21-26-34-000-001 and AMM 21-26-34-400-001.
*** If there is no 28VDC:
*** - Do a check of the wiring ASM 212603 between:
*** . The AEVC (10HQ) pin AA/8A and the blower fan control-contactor (8HQ) pin Z
*** . The blower fan control-contactor (8HQ) pin X and the blower fan (20HQ) pin A/D.
**** If the wiring is not correct:
**** - Repair the related wiring.
**** If the wiring is correct:
**** - ReplaceCNTOR-BLOWER FAN CTL, AVNCS VENT (8HQ) .
**** If the fault continues:
**** - Replace FAN-BLOWER, AVNCS VENT [20HQ] AMM 21-26-51-000-001 and AMM 21-26-51-400-001.
b If the AIR COND/AVNCS/VENT/MONG circuit breaker (3HQ) is open:
Subtask 21-26-00-710-091-A - Make sure that the avionics ventilation filter is clean.
- Do the procedure (Ref. TSM TASK 24-00-00-810-803).
- Replace
CNTOR-BLOWER FAN CTL, AVNCS VENT (8HQ) .
- Replace FAN-BLOWER, AVNCS VENT [20HQ] AMM 21-26-51-000-001 and AMM 21-26-51-400-001.
- Replace C/B-AVNCS VENT/BLOWER/FAN [1HQ] .
- Replace CARTRIDGE-AVNCS VENT FILTER [2082HM] AMM 21-26-43-920-001.
- Replace FAN-BLOWER, AVNCS VENT [20HQ] AMM 21-26-51-000-001 and AMM 21-26-51-400-001.
- Replace AEVC [10HQ] AMM 21-26-34-000-001 and AMM 21-26-34-400-001.
- Do a check of the status of the AVNCS VENT/BLOWER/FAN circuit breaker (1HQ).
- Do a check for 115VAC at pins A/J, A/K and A/L of the blower fan (20HQ).
- Do a check for 115VAC at pins T1, T2 and T3 of the blower fan control-contactor (8HQ).
- Do a check of the wiring ASM 212603 between:
. the blower fan control-contactor (8HQ), pins L1, L2 and L3 and the circuit breaker (1HQ), pins A2, B2 and C2.
- Repair the related wiring.
- Replace C/B-AVNCS VENT/BLOWER/FAN [1HQ]
- Do a check of the status of the AIR COND/AVNCS/VENT/MONG circuit breaker (3HQ).
- Do a check for 28VDC at pin A/E of the blower fan (20HQ).
* If there is no 28VDC:
* - Do a check of the wiring ASM 212603 between:
* . The blower fan (20HQ) pin A/E and the AIR COND/AVNCS/VENT/MONG circuit breaker (3HQ)
* . The blower fan (20HQ) pin A/F and the ground.
** If the wiring is not correct:
** - Repair the related wiring.
** If the wiring is correct:
** - Replace C/B-AIR COND/AVNCS/VENT/MONG [3HQ] .
* If there is 28VDC:
* - Make sure that the warning light of the blower fan (20HQ) is off.
** If the warning light is on, push the RESET pushbutton switch on the blower fan (20HQ).
NOTE: The fan starts immediately.
The warning light goes off.
** If the fault continues: The warning light goes off.
** - Replace FAN-BLOWER, AVNCS VENT [20HQ] AMM 21-26-51-000-001 and AMM 21-26-51-400-001.
** If the fault continues:
** - Do a check for 28VDC at pin AA/8A of the AEVC (10HQ) ASM 212603.
*** If there is 28VDC:
*** - Replace AEVC [10HQ] AMM 21-26-34-000-001 and AMM 21-26-34-400-001.
*** If there is no 28VDC:
*** - Do a check of the wiring ASM 212603 between:
*** . The AEVC (10HQ) pin AA/8A and the blower fan control-contactor (8HQ) pin Z
*** . The blower fan control-contactor (8HQ) pin X and the blower fan (20HQ) pin A/D.
**** If the wiring is not correct:
**** - Repair the related wiring.
**** If the wiring is correct:
**** - Replace
**** If the fault continues:
**** - Replace FAN-BLOWER, AVNCS VENT [20HQ] AMM 21-26-51-000-001 and AMM 21-26-51-400-001.
b If the AIR COND/AVNCS/VENT/MONG circuit breaker (3HQ) is open:
- Do the procedure (Ref. TSM TASK 24-00-00-810-803).
* If the fault continues:
* - Replace C/B-AIR COND/AVNCS/VENT/MONG [3HQ] .
- Replace FAN-BLOWER, AVNCS VENT [20HQ] AMM 21-26-51-000-001 and AMM 21-26-51-400-001.
- Replace PRESS SW-BLOWER FAN, AVNCS VENT [17HQ] AMM 21-26-11-000-001 and AMM 21-26-11-400-001.
- Replace PRESS SW-BLOWER FAN, AVNCS VENT [19HQ] AMM 21-26-11-000-001 and AMM 21-26-11-400-001.
B. Do the operational test given in Para. 3.