Failure of the Conditioned Air-Inlet Valve


TASK 21-26-00-810-805-A
Failure of the Conditioned Air-Inlet Valve


1. Possible Causes
  • VALVE-COND AIR INLET, AVNCS VENT [21HQ]
  • wiring between the AEVC (10HQ) and the conditioned air-inlet valve (21HQ)
  • AEVC [10HQ]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 21-26-00-710-001
Operational Check of the Avionics Equipment Ventilation-System via MCDU
AMM 21-26-00-710-008
Operational Test to Read the CFDS for CLASS 3 Faults of the AEVC
AMM 21-26-00-710-009
Operational Test to Read the CFDS for LAST LEG REPORT of the AEVC
ASM 212603
AMM 21-26-34-000-001
Removal of the Avionics Equipment Ventilation Computer (AEVC)
AMM 21-26-34-400-001
Installation of the Avionics Equipment Ventilation Computer (AEVC)
AMM 21-26-54-000-001
Removal of the Conditioned Air Inlet Valve
AMM 21-26-54-400-001
Installation of the Conditioned Air Inlet Valve
3. Fault Confirmation
Subtask 21-26-00-865-059-A
A. Table of the circuit breakers used in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
122VUAIR COND/AVNCS/VENT/MONG3HQY17
Subtask 21-26-00-710-084-A
B. Test
   (1) Do the reset of the AEVC (10HQ).
     (a) Open the circuit breaker AIR COND/AVNCS/VENT/MONG (3HQ).
     (b) Wait for five seconds.
     (c) Close the circuit breaker AIR COND/AVNCS/VENT/MONG (3HQ).
   (2) Do the operational test of the avionics equipment ventilation from the Multipurpose Control and Display Unit (MCDU) AMM 21-26-00-710-001.
   (3) Read the LAST LEG REPORT of the AEVC AMM 21-26-00-710-009.
   (4) Read the CLASS 3 faults of the AEVC AMM 21-26-00-710-008.
4. Fault Isolation
Subtask 21-26-00-810-069-A
A. If the test gives the maintenance message COND AIR INLET V 21HQ:
  • Do a check of the status of the conditioned air-inlet valve (21HQ) microswitches, between pin A/J and pin A/G and between pin A/M and pin A/K ASM 212603.
   (1) If the status of the microswitch between the pin A/J and the pin A/G is the same as the status of the microswitch between the pin A/M and the pin A/K:
   (2) If the status of the microswitch between the pin A/J and the pin A/G is not the same as the status of the microswitch between the pin A/M and the pin A/K:
  • Do a check for a ground signal at pin A/U, pin A/G, pin A/K of the conditioned air-inlet valve (21HQ) ASM 212603.
     (a) If there is no ground signal:
  • Repair the related wiring.
     (b) If there is a ground signal:
  • Do a check of the wiring between the AEVC (10HQ) and the conditioned air-inlet valve (21HQ) ASM 212603:
    . Pin AB/7A and pin A/J
    . Pin AB/7B and pin A/M.
       1 If the wiring is not correct:
  • Do a check of the wiring between the AEVC (10HQ) and the conditioned air-inlet valve (21HQ) ASM 212603:
    . Pin AA/7A and pin A/A
    . Pin AA/7B and pin A/C.
       2 If the wiring is correct:
Subtask 21-26-00-710-085-A
B. Do the operational test given in Para. 3.