Failure of the Skin Air-Outlet Valve


TASK 21-26-00-810-804-A
Failure of the Skin Air-Outlet Valve


1. Possible Causes
  • VALVE-SKIN AIR OUTLET, AVNCS VENT [22HQ]
  • wiring between the AEVC (10HQ) and the skin air-outlet valve (22HQ)
  • AEVC [10HQ]
  • wiring between the AEVC (10HQ) and the SDAC-1 (1WV1) and/or SDAC-2 (1WV2)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 21-26-00-710-001
Operational Check of the Avionics Equipment Ventilation-System via MCDU
AMM 21-26-00-710-008
Operational Test to Read the CFDS for CLASS 3 Faults of the AEVC
AMM 21-26-00-710-009
Operational Test to Read the CFDS for LAST LEG REPORT of the AEVC
ASM 212602
AMM 21-26-34-000-001
Removal of the Avionics Equipment Ventilation Computer (AEVC)
AMM 21-26-34-400-001
Installation of the Avionics Equipment Ventilation Computer (AEVC)
AMM 21-26-42-200-002
Inspection/Check of the Skin Heat Exchanger (Outlet Duct)
AMM 21-26-53-000-002
Removal of the Skin Air Outlet-Valve
AMM 21-26-53-400-001
Installation of the Skin Air Outlet-Valve
3. Fault Confirmation
Subtask 21-26-00-865-058-A
A. Table of the circuit breakers used in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
122VUAIR COND/AVNCS/VENT/MONG3HQY17
Subtask 21-26-00-710-080-A
B. Test
   (1) Do the reset of the AEVC (10HQ).
     (a) Open the circuit breaker AIR COND/AVNCS/VENT/MONG (3HQ).
     (b) Wait for five seconds.
     (c) Close the circuit breaker AIR COND/AVNCS/VENT/MONG (3HQ).
   (2) Do the operational test of the avionics equipment ventilation from the Multipurpose Control and Display Unit (MCDU) AMM 21-26-00-710-001.
   (3) Read the LAST LEG REPORT of the AEVC AMM 21-26-00-710-009.
   (4) Read the CLASS 3 faults of the AEVC AMM 21-26-00-710-008.
4. Fault Isolation
Subtask 21-26-00-810-101-A
A. If the test gives the maintenance message SKIN AIR OUTLET V 22HQ and the logbook or the Post Flight Report (PFR) gives the ECAM warning VENT BLOWER FAULT:
Subtask 21-26-00-810-067-A
B. If the test gives the maintenance message SKIN AIR OUTLET V 22HQ and the logbook or the Post Flight Report (PFR) does not give the ECAM warning VENT BLOWER FAULT:
  • Do a check of the status of the skin air-outlet valve (22HQ) on the lower ECAM display unit.
   (1) If the valve symbol is green:
  • Do a check and repair the wiring between the AEVC (10HQ) and the skin air-outlet valve (22HQ) ASM 212602:
    . Pin AA/3A and pin A/A
    . Pin AA/3B and pin A/C
    . Pin AA/3C and pin A/E.
   (2) If the valve symbol is amber:
  • Do a check and repair the wiring between the AEVC (10HQ) and the skin air-outlet valve (22HQ) ASM 212602:
    . Pin AB/3A and pin A/J
    . Pin AB/3B and pin A/M
    . Pin AB/3C and pin A/R.
   (3) If the fault continues:
     (a) If the fault continues:
   (4) If the fault continues:
  • Do a check and repair the wiring between the AEVC (10HQ) and the SDAC-1 (1WV1) and/or SDAC-2 (1WV2), pin AB/8A and pin AD/12C ASM 212602.
Subtask 21-26-00-710-081-A
C. Do the operational test given in Para. 3.