Loss of the Automatic Control and Monitoring of the Valves and Fans
TASK 21-26-00-810-801-A
Loss of the Automatic Control and Monitoring of the Valves and Fans
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 21-26-00-865-050-A
Subtask 21-26-00-810-050-D ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:38:49 UTC
Loss of the Automatic Control and Monitoring of the Valves and Fans
1. Possible Causes
- CARTRIDGE-AVNCS VENT FILTER [2082HM]
- AEVC [10HQ]
wiring between the AEVC pin AA/1D and the ground terminal - C/B-AIR COND/AVNCS/VENT/MONG [3HQ]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 24-00-00-810-803-A | Circuit Breaker Tripped and/or C/B TRIPPED Warning |
| AMM 21-26-00-710-001 | Operational Check of the Avionics Equipment Ventilation-System via MCDU |
| AMM 21-26-00-710-008 | Operational Test to Read the CFDS for CLASS 3 Faults of the AEVC |
| AMM 21-26-00-710-009 | Operational Test to Read the CFDS for LAST LEG REPORT of the AEVC |
| ASM 212601 | |
| ASM 212603 | |
| AMM 21-26-34-000-001 | Removal of the Avionics Equipment Ventilation Computer (AEVC) |
| AMM 21-26-34-400-001 | Installation of the Avionics Equipment Ventilation Computer (AEVC) |
| AMM 21-26-43-600-016 | Discard Demister Filter Element and Filter Cartridge (LE BOZEC) |
| AMM 21-26-43-920-001 | Discard the Filter Cartridge (PALL) |
Subtask 21-26-00-865-050-A
A. Table of the circuit breakers used in this procedure:
Subtask 21-26-00-710-050-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 122VU | AIR COND/AVNCS/VENT/MONG | 3HQ | Y17 |
B. Test
(1) Do the reset of the AEVC (10HQ).
(a) Open the circuit breaker AIR COND/AVNCS/VENT/MONG (3HQ).
(b) Wait for five seconds.
(c) Close the circuit breaker AIR COND/AVNCS/VENT/MONG (3HQ).
(2) Do the operational test of the avionics equipment ventilation from the Multipurpose Control and Display Unit (MCDU) AMM 21-26-00-710-001.
(3) Read the LAST LEG REPORT of the AEVC AMM 21-26-00-710-009.
(4) Read the CLASS 3 faults of the AEVC AMM 21-26-00-710-008.
4. Fault Isolation(1) Do the reset of the AEVC (10HQ).
(a) Open the circuit breaker AIR COND/AVNCS/VENT/MONG (3HQ).
(b) Wait for five seconds.
(c) Close the circuit breaker AIR COND/AVNCS/VENT/MONG (3HQ).
(2) Do the operational test of the avionics equipment ventilation from the Multipurpose Control and Display Unit (MCDU) AMM 21-26-00-710-001.
(3) Read the LAST LEG REPORT of the AEVC AMM 21-26-00-710-009.
(4) Read the CLASS 3 faults of the AEVC AMM 21-26-00-710-008.
Subtask 21-26-00-810-050-D ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message NO RESPONSE:
Subtask 21-26-00-810-050-E ** ON A/C NOT FOR ALL - make sure that the avionics ventilation filter is not dirty. If necessary, replace the CARTRIDGE-AVNCS VENT FILTER [2082HM] AMM 21-26-43-920-001.
- Do a check of the status of the circuit breaker (3HQ).
- Do a check for 28VDC at pin AA/1A of the AEVC (10HQ) ASM 212603.
- Do a check for a ground signal at pin AA/1D of the AEVC (10HQ) ASM 212601.
- Replace the AEVC [10HQ] AMM 21-26-34-000-001 and AMM 21-26-34-400-001.
- Repair the
wiring between the AEVC pin AA/1D and the ground terminal .
- Do a check of the wiring between the AEVC pin AA/1A and the circuit breaker (3HQ) ASM 212603.
- Repair the related wiring.
- Replace the C/B-AIR COND/AVNCS/VENT/MONG [3HQ] .
- Do the procedure (Ref. TSM TASK 24-00-00-810-803).
- Replace the C/B-AIR COND/AVNCS/VENT/MONG [3HQ] .
- Replace the AEVC [10HQ] AMM 21-26-34-000-001 and AMM 21-26-34-400-001.
A. If the test gives the maintenance message NO RESPONSE:
Subtask 21-26-00-710-051-A - Make sure that the avionics ventilation filter is not dirty. If necessary, replace CARTRIDGE-AVNCS VENT FILTER [2082HM] AMM 21-26-43-600-016.
- Do a check of the status of the circuit breaker (3HQ).
- Do a check for 28VDC at pin AA/1A of the AEVC (10HQ) ASM 212603.
- Do a check for a ground signal at pin AA/1D of the AEVC (10HQ) ASM 212601.
- Replace the AEVC [10HQ] AMM 21-26-34-000-001 and AMM 21-26-34-400-001.
- Repair the
wiring between the AEVC pin AA/1D and the ground terminal .
- Do a check of the wiring between the AEVC pin AA/1A and the circuit breaker (3HQ) ASM 212603.
- Repair the related wiring.
- Replace the C/B-AIR COND/AVNCS/VENT/MONG [3HQ] .
- Do the procedure (Ref. TSM TASK 24-00-00-810-803).
- Replace the C/B-AIR COND/AVNCS/VENT/MONG [3HQ] .
- Replace the AEVC [10HQ] AMM 21-26-34-000-001 and AMM 21-26-34-400-001.
B. Do the operational test given in Para. 3.